AIRCUT
-101
I
,161
IW
,200
IW Inverter Plasma Cutting Machine
WARPP ENGINEERS PVT LTD
27
6)
Check if the water in compressed air filter fixed at the back of machine is drained
regularly
;
7)
Check if the gas pressure indicator lamp on the panel is ON. If it is not ON, check if
compressed gas pipe is well connected , and if the gas pressure is normal. When the
gas pressure is less than 0.3Mpa, the lamp is not ON.
8)
When the water cooling torch is applied, check if the water pressure indicator lamp
on panel is ON. If it is not ON, check if the cooling water current is normal.
9)
Check if the overheat indicator lamp on panel is ON. If yes, check if the temperature
relay on the radiator is damaged or not.
10)
Openthe machine top to check if the lead-typed fuse next to the control transformer
has been fused
;
Ordinary trouble and repair as following sheet
Trouble
Reasons
Solutions
1. When the power
1.Three-phase power misses phase 1.Check three-phase power source
is switched on, the
2.Supply power switch is damaged 2.Change power switch
lamp and the digital 3.Power control fuse 3A is broken
3.Change power control fuse
meter are not ON.
2
.
Supply abnormal
indicator lamp is ON
without arc striking
1
.
Three-phase power misses
phase
2. Three-phase power is overload
under voltage
Check three-phase power source to
ensure the supply voltage accords with
the supply requirements.
3. No arc striking or 1
.
Theambient temperature is too
high.
2
.
When cutting, cooling fan
rotates slowly or do not rotate, so
the cooling effect is weak.
3
.
Temperaturerelayis damaged
1
.
Let the cutter rest for a while,
and
will come to work normally later.
2
.
Check fan power source or
change cooling fan
3
.
Change temperature relay
arc breaking during
cutting.
Overheat
indicator lamp
is
ON.
4
.
It cannot
start. Gas pressure
lamp is
not ON.
1
.
No gas pressure
2
.
The gas supply pressure is
too
low
3. LGK AP1 is damaged
1
.
connect the gas source
2. Adjust gas supply pressure
3. change LGK AP1..
5. no arc striking,
1
.
Cutting ground wire is not well
connected.
2
.
Gas pressure is too high.
3
.
Torch electrode and nozzle
are badly broken.
4
.
Torch electrode and arc striking
wire is short circuit, which cause
the damage of torch.
5. HF board is damaged.
1
.
Connect the cutting ground wire well
2
.
Lower the gas supply pressure
3
.
Change the electrode and nozzle
4
.
Change the torch
5.
Change HF board
cutting
indicator
lamp, gas pressure
lamp are ON, and
power
supply
abnormity indicator
lamp and overheat
lamp are not ON.
1
.
Gas pressure is too high or too 1
.
Adjust gas pressure
low.
2. Water draining regularly
2. The Air filter regulator cup is
3
.
The thickness of workpiece
should
6.
Weak
cutting
quality
filled.
3
.
Work-piece is too thick
4
.
Torchelectrode and nozzle
are
be within the quality cuttingrange.
4
.
Change electrode and nozzle
5
.
Adjust torch angle
broken
6
.
Adjust cutting speed