AIRCUT
-101
I
,161
IW
,200
IW Inverter Plasma Cutting Machine
WARPP ENGINEERS PVT LTD
14
5
、
The connection of compressed air and the operation of pressure regulating
filter (The function of pressure regulating filter please check the below figure)
Gas pressure
regulating valve
Hoop
Inlet pipe
Draining water tip
1)
The compressed gas should meet the requirement mentioned in point “Plasma gas
conditions”. Connect the gas pipe with the gas inlet of air filter on the back panel
and hoop ittightly.
2)
Theusage of pressure regulating filter is as follows. Whenit is to adjust pressure, lift
upair pressureregulating valve, androtate it. Left rotation aims to reduce outlet gas
pressure, right rotation aims to increase outlet gas pressure. After the gas pressure
is adjusted properly, press down regulating valve.
3)
The air filter regulator should be checked periodically. If the water level reaches
two-thirds of filter glass, it must be drained, or this will affect incision quality. The
gas supply valve should be closed during water draining, and Gas Checking function
is selected in panel. When the indicated valve of gas pressure meter is zero, water
will drain out from drainage mouth automatically.
6
、
Connection of cooling water (
AIRCUT
101 I does not have this function)
Connect the copper nozzle marked with “water inlet” on the cutter rear side with
water supply pipe, and tighten it. Connect the copper nozzle marked with
“Backwater” with water recycle pipe, and tighten it.
Notes: when use gas cooling torch, the torch selection switch on panel must be set
to air-cooled torch position, and the cooling water cannot be connected with. The
cooling water is for cooling torch only, and cutter power source does not need water
cooling.
7
、
The connection of output terminal
1)
The connection oftorch
The torch model matched to plasma power source is as below:
Model
AIRCUT
101I
AIRCUT
-
161 IW
AIRCUT
-
200IW
Torch
model
P80
Air cooling
160
Water cooling
200
Water cooling
Remarks
Also work with P80 under 120A
current