In all cases, the installation of this appliance must conform with all 
national, state/provincial, local and applicable codes for the installation of 
gas fired appliances.  Only persons familiar with such codes and certified 
for the installation of gas appliances are authorized to install Patio Plus 
heaters.  Improper installation, maintenance or adjustment of Patio Plus 
heaters can cause serious injury, property damage or death.  

Clearances & Safe Mounting Practices.

Each heater must be installed so that the following “minimum clearances to combustibles” 
are maintained.  Combustible materials are considered to be wood, compressed paper, 
plant fibres, or other materials capable of being ignited and burned.    Such materials shall 
be considered combustible even though flame-proofed, fire retardant treated or plastered.  
Additional clearances may be required for glass, painted surfaces, plastics, vinyl and other 
materials which may be damaged or melted by radiant or convection heat.  A minimum 
clearance of 24 inches (above the heater) must be maintained to plastics, vinyl or any 
other materials that may be adversely affected by radiant or convection heat.

“ABOVE”
Minimum
16”

“SIDE”
Minimum
30”

“BELOW”
Minimum
30”

“BELOW”
Minimum 84”
above ground / floor

“SIDE”
Minimum
30”

Warning:  The clearances 
below are also applicable 
to items that may be 
stored below heaters.  
These clearances apply to 
both natural gas and 
propane heaters.

Содержание Patio Plus

Страница 1: ...asy Radiant Works accepts no responsibility for damages whatsoever resulting in improper installation of this heater Improper installation voids all warranties This manual must remain with the heater...

Страница 2: ...red to be wood compressed paper plant fibres or other materials capable of being ignited and burned Such materials shall be considered combustible even though flame proofed fire retardant treated or p...

Страница 3: ...osed Patios Enclosed patios must be large enough to meet the clearance to combustibles and ventilation requirements as provided for in all applicable codes For very small enclosed patios Patio Plus he...

Страница 4: ...e kept clean 6 WARNING gas leaks are extremely dangerous and potentially explosive Do not use this product until a leak is repaired Easy Testing Procedure 1 Prepare a cup of soapy water 2 Attach regul...

Страница 5: ...ing options PH 45 H LP Liquid Propane PH 50 H N Natural Gas Hanging Units PH 45 H R LP Liquid Propane PH 50 H R N Natural Gas Hanging Units with 24 volt remote switching option PH 45 IG LP Liquid Prop...

Страница 6: ...heater and be sure to check all connections each time the cylinder is connected Always turn off the gas supply to the heater at the cylinder as soon as you are finished using the heater The L P cylin...

Страница 7: ...the heater head hose assembly into the 3 post The top of the post can be identified by the 3 8 hole being at the top end Line up the 3 8 hole in the post with the 3 8 hole in the base of the heater he...

Страница 8: ...ide the decorative cover onto the post from the bottom Place the post into the basemount T on the weighted base and slide the decorative cover down over the post retainer Connect gas supply to nipple...

Страница 9: ...t Aline the 3 8 hole in the post with the 3 8 threaded hole in the base of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Slide the decorative cover onto the post from the bottom P...

Страница 10: ...se of the heater head and replace the 3 8 x 1 bolt Secure tightly Step 4 Insert post into the ground support pipe and fasten with hardware provided Connect the gas supply to the nipple protruding from...

Страница 11: ...ess cannot be created on the gas supply piping Step 3 Apply a suitably approved pipe sealant to the nipple protruding from the bottom of the hanging bracket Turn the heater head onto the nipple to ach...

Страница 12: ...ank or other system After pilot is lit and it is mistakenly turned off the knob will be in an immovable position Wait 90 seconds and the thermocouple will cool and knob will be released to re light pi...

Страница 13: ...Defective gas valve Dirty pilot Replace thermopile Replace gas valve Clean pilot Main Burner won t light No 24 Volt power to unit Low gas pressure Blockage in orifice Manual valve not in on position...