background image

IMPORTANT INFORMATION 

 

1.  Check local installation codes for your area. 
 
2.  Read and comply with the instructions in this manual. 
 
3.  This unit should be tested (dry run) before loading pellets. 

 

 
4.   Your stove is designed to burn Premium Hardwood Pellets. Pellets with a high ash  
      content will burn dirty and the unit will need cleaning more frequently. 
 
5.  Be sure your pellets are not damp or wet. Keep sawdust out of the unit.  
   

  

6.  Use 3” PELLET VENT PIPE with this stove and follow the manufacturer’s specifications 

for installation and clearances. Even though this pipe interlocks it is a good idea to seal 
all connections with high temperature silicone. 

 

7.  An outside combustion air connection is mandatory for this unit to work properly. Make this 

connection using a 1 

7

/

8

” I.D. metal pipe (steel, aluminum or copper) and coupler. Be sure to 

secure the pipe to the unit with aluminum tape or a clamp.  Our part number PU-OAK 
(Outside Air Kit) can be used.  The outside end should be covered (screened) to prevent any 
foreign matter from getting into the system. 

 

8.  Regularly inspect the ash build-up in the burn pot and, if any crust forms remove it from 

the burn pot with a poker. 

 

9.  The ash in the burn pot should be removed regularly, depending on your burn rate. The area 

to the right and left of the burn pot is for ash storage; keep the air holes in the burn pot clean 
for a more efficient burn. You should also frequently check the exhaust system. 

 

10. Keep pellets and all other combustible materials a safe distance from the stove. 
 
11. This unit will require floor protection if it is installed on a combustible surface.  

The minimum floor protector for this stove is 36” x 36” which should give you at least one 
inch (1”) of protection at the rear, four inches (4”) on each side and six inches (6”) 
minimum in the front of the unit.  

 
12. Horizontal runs should not exceed four feet (4’) with a maximum vertical flue  
      height of thirty five feet (35’). At a height of fifteen feet (15’) the pipe should be      
      increased to 4” PELLET VENT PIPE. 
 
13. This unit should be turned off and allowed to cool prior to cleaning. Any ashes should be 

kept in an airtight metal container completely away from all combustibles and should not 
be disposed of until they are completely cooled. 

 
14. Read the instructions thoroughly concerning the various settings that are available  

with the digital read-out control board.   

Visit our web site at 

www.englandsstoveworks.com

 for helpful information,  

frequently asked questions, parts & accessory orders and more.  

 

 

 

UNIT PREPARATION 

Do not allow paint, chemicals or construction dust on or near your unit.  Do not allow liquid or ANY 
foreign materials on or inside your unit.  Shut your unit down and cover it when painting, construction or 
similar activity is taking place.  Wipe and clean your unit after any construction is done in your home, or if 
any foreign material gets on or inside your unit.  You may also need to remove the rear and side cover plates 
to your unit (unplug unit first) and vacuum and clean the motors and inside of your unit.

Содержание 25-PAF

Страница 1: ...ding and fire codes Please read this entire manual before installation and use of this pellet fuel burning add on furnace Keep children furniture fixtures and all combustibles away from any heating ap...

Страница 2: ...guide on our web site we have always tried to help our customers stay heat ready especially when oil and electricity prices continue to skyrocket Please look at our vast Help section on our web site...

Страница 3: ...k the exhaust system 10 Keep pellets and all other combustible materials a safe distance from the stove 11 This unit will require floor protection if it is installed on a combustible surface The minim...

Страница 4: ...lings Check local codes in your area This unit is equipped with a negative draft system that pulls air through the burn pot and pushes the exhaust out of the dwelling If this unit is connected to a fl...

Страница 5: ...e thimble or pipe will be either six inches 6 or eight inches 8 and the proper reducer 3 to 6 or 3 to 8 can be purchased or ordered by your local dealer Connect a three inch 3 tee with clean out to th...

Страница 6: ...bs total 3 Close hopper lid and secure the latches 4 Place a handful of pellets in the burn pot spread a small amount of fire starter over the top and ignite the pellets Wait a few minutes before clos...

Страница 7: ...for more than 18 minutes the unit will have to be re started completely see Start Up Procedure NOTE The unit will also shut down in the event of Combustion Blower failure if this is the case the unit...

Страница 8: ...ove the burn pot assembly clean it thoroughly and re install it refer to Exploded View this will require new gasket for the burn pot Be sure to tighten the set screws when you replace them but do not...

Страница 9: ...blower exhaust tube on the stove should be brushed and vacuumed When cleaning or replacing the blower a new gasket should be added between the blower flange and the steel exhaust tube Gaskets This uni...

Страница 10: ...r exit Thirty gauge or thicker pipe should run from the top of the furnace to the hot air trunk line of your existing hot air system Using the least possible amount of pipe will help the heat transfer...

Страница 11: ...I D Pipe see manual 3 Min NOTE 1 If 3 flue pipe exceeds 15 in length increase to 4 flue pipe for remaining flue connections 2 Total flue length should not exceed 35 3 Horizontal run not to exceed 4 4...

Страница 12: ...Low Burn Heat Range setting 1 Room Air Blower setting 1 Medium Low Heat Range setting 2 3 Room Air Blower setting Medium High Heat Range setting 5 8 Room Air Blower setting High Burn Heat Range settin...

Страница 13: ...d on our pellet units as long as it is a 24 volt that works with millivolt systems After unplugging the unit locate the jumper wire J 18 on the bottom of the control panel The two screws should then b...

Страница 14: ...curs because of an accident improper handling improper operation improper installation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental...

Страница 15: ...1376 850 CFM CONVECTION BLOWER PU CB98 DIGITAL CONTROL BOARD PU 62 40 151 2 Hopper Lid Latch 2002 and later Models for earlier models order PU 103 50 PU AF6T TOP AUGER SHAFT W FLIGHTING PU AF11B BOTTO...

Страница 16: ...Pellet Stove Exploded View...

Страница 17: ...oard settings 1 Review board settings 2 Bad exhaust blower 2 Replace blower 3 Excessive pellet moisture 3 Keep pellets inside 4 Excessive ash 4 Remove baffles Clean unit 5 Low quality pellets 5 Use pr...

Страница 18: ......

Страница 19: ...s _________________________________________________________ City ________________________ State __________ Zip _________________ UNIT INFORMATION Model Number _____________________ Purchase Date _____...