Installation Control Housings
A. Wall/Shelf Mounting
The tongue and groove joints on the sides of each
housing module allow any number of them to be
joined together to form one housing.
1. Connecting the Housings
❑
a. Remove the PC Board assemblies from the
housings, if installed by loosening the two
captive screws on each front panel and sliding
the assemblies out.
❑
b. Loosen the latches holding the two part
housings together and separate the two pieces.
The latches are located on the inside tops and
bottoms of the housing.
❑
c. Working from right to left, join the rear sections
of each housing by sliding them together.
Repeat the process for the front sections, but do
not fasten them together yet.
2. Wall Mounting
❑
a. If bottom-entry conduit entrance is required,
remove the L-shaped bracket and discard it.
Reinsert the screws into the control after the
bracket has been removed.
❑
b. Using the dimensions shown Figure 1, page
5, drill four (4) 13/64” mounting holes for each
housing to provide clearance for #10 bolts.
❑
c. Apply the terminal strip label supplied with the
control logic module to the PC Board as shown
in Figure 2, page 6.
CAUTION: Be sure to apply the label in the proper
position with the brake (+) terminal at
the top.
❑
d. Mount the rear sections loosely to the mounting
surface. Do not connect the front sections yet.
The controls are now ready to be wired. Proceed to
the wiring section of this manual for the appropriate
wiring instructions.
3. Shelf Mounting
❑
a. If bottom conduit-entrance is required remove
the two (2) screws attaching the brackets to
the housing. Rotate the brackets to face away
from the housings and reinsert and tighten the
screws.
❑
b. Using the dimensions shown in Figure 1, page
5, drill your (4) 13/64” mounting holes for each
housing to provide clearance for #10 bolts.
❑
c. Apply the terminal strip label supplied with the
control logic module to the PC Board as shown
in Figure 2, page 6.
CAUTION: Be sure to apply the label in the proper
position with the brake (+) terminal at
the top.
❑
d. Mount the rear sections loosely to the mounting
surface. Do not connect the front sections yet.
The controls are now ready to be wired. Proceed to
the wiring section of this manual for the appropriate
instructions.
Figure 1. Wall/shelf enclosure dimensions
Содержание MCS-204
Страница 1: ...Tension Control System MCS 166 MCS 203 MCS 204 Installation Operation Instructions P 0257 WE 819 9027...
Страница 16: ...16 Warner Electric 800 825 9050 P 0257 WE 819 9027 Figure 13 Control Adjustment Locations MCS 166 MCS 203...