background image

TOWEL WARMER INSTALLATION INSTRUCTIONS

8

WARMUP INC. 

USA: [email protected] | Tel.: 1-888-927-6333 | www.warmup.com

CANADA: [email protected] | Tel.: 1-888-592-7687 | www.warmup.ca

With TW001 and TW002 models, the j-box or connection point will be located away from the bottom right of your towel warmer. 

This can either be near the appliance or directly into a switch box or gang box hosting your Warmup 4iE controller (optional). 

 

Do note that the leads exiting each bar are 3ft in length. Do not extend these leads in the wall outside of a code compliant junction 

box. It is not safe to make electrical connections outside of a junction box.

 

Please ensure you comply to all local and national code requirements in regards to line voltage wire in conduit. State and local 

regulations vary (flex conduit, rigid conduit or neither) and must be respected to avoid electrical hazards.

 

The installation of this model requires access behind the drywall and should be completed before hanging drywall. In other 

instances, mark the placement of the towel warmer and cut out the drywall at least 6” wider around the towel warmer.  

Remove the drywall cutout from the wall and proceed with mounting instructions below:

 

1.  Mount the concealed cable mushroom into the wall where the lower right hand bracket will be located  

(lower right as you look at the mounted towel warmer on the wall)

2. 

Ensure you have a code compliant connection between the mushroom anchor and your electrical connection in the j-box.

3.  Determine the other anchor points and secure the wall anchors accordingly.

 

a) This will be specifically identified by the location of the mounting bracket bar secured to the back of the drywall panel

4.  You must ensure that the left side of the towel warmer is secured to wood or metal studs or a structural element.

5.    Your lead wires are 3ft leaving each bar. You can trim it to your needs leaving no less than 12” outside of the towel warmer

6.   Sleeve the cables through the wall anchor mushrooms and fish them through to your electrical connection. All electrical   

      connections and wiring must be compliant with local and national electrical codes. Please check with a licensed electrician.

7.    Finally safely push your towel bars into place and tighten the grub screws underneath each bracket.

CONCEALED CORD ENTRY WITH REMOTE J-BOX

Your package includes:

1

4

2

5

3

6

7

x1

x1

x3

x1

Mushroom kit with 
screw and washer

Содержание TW080

Страница 1: ...TOWEL WARMERS INSTALLATION INSTRUCTIONS Towel Warmer Installation Instructions...

Страница 2: ...t require a control Our proprietary heating technology inside the towel warmer will ensure the device reaches 145F degrees in 3 minutes If your goal is to get the comfort of a nice warm towel after th...

Страница 3: ...he other 1 4 7 1 2 5 8 2 3 6 9 C CODE TUBE SHAPE BARS FINISH VOLTAGE AMPERAGE RESISTANCE TW001 Round 1 4 Polished Stainless 120V 0 075A 1600 TW002 Square 1 4 Brushed Nickel 120V 0 075A 1600 TW080 Squa...

Страница 4: ...r The towel warmer should NOT be used for anything other than its intended use of warming up and drying bathroom towels Occasionally wipe down your towel warmer from time to time with a damp cloth and...

Страница 5: ...g area toilet vanity etc The left side of your towel warmer most be anchored into a stud Use a stud finder tool to locate the 2x4 behind your drywall and mark it with a pencil Hold your towel warmer l...

Страница 6: ...cover plate from the lower right hand bracket 7 Sleeve the cable through the wall anchor mushroom and fish it through to your electrical connection All electrical connections and wiring must be compl...

Страница 7: ...ividual heated bars installed horizontally in a landscape direction one on top of the other to create an aesthetic floating ladder feature in the bathroom The installation of this model requires acces...

Страница 8: ...er Remove the drywall cutout from the wall and proceed with mounting instructions below 1 Mount the concealed cable mushroom into the wall where the lower right hand bracket will be located lower righ...

Страница 9: ...ired to return the defective product for assessment at your cost Register your warranty online http www warmup com register warranty This warranty does not cover any installation or removal costs The...

Страница 10: ...com Tel 1 888 592 7687 www warmup ca N White 1 8m L Black 1 8m E Green 1 8m N White 1 8m L Black 1 8m E Green 1 8m CODE TUBE SHAPE BARS FINISH VOLTAGE AMPERAGE RESISTANCE TW082 Square 5 Polished Stain...

Страница 11: ...m Tel 1 888 592 7687 www warmup ca TOWEL WARMER INSTALLATION INSTRUCTIONS 1200 400 1200 267 7 1076 7 153 3 953 3 1200 115 4 22 25 4 400 115 4 N White 1 8m L Black 1 8m E Green 1 8m CODE TUBE SHAPE BAR...

Страница 12: ...com Tel 1 888 592 7687 www warmup ca N White 1 8m L Black 1 8m E Green 1 8m N White 1 8m L Black 1 8m E Green 1 8m CODE TUBE SHAPE BARS FINISH VOLTAGE AMPERAGE RESISTANCE TW090 Round 6 Polished Stain...

Страница 13: ...www warmup com CANADA ca warmup com Tel 1 888 592 7687 www warmup ca TOWEL WARMER INSTALLATION INSTRUCTIONS N White 1 8m L Black 1 8m E Green 1 8m CODE TUBE SHAPE BARS FINISH VOLTAGE AMPERAGE RESISTAN...

Страница 14: ...com Tel 1 888 592 7687 www warmup ca N White 1 8m L Black 1 8m E Green 1 8m N White 1 8m L Black 1 8m E Green 1 8m CODE TUBE SHAPE BARS FINISH VOLTAGE AMPERAGE RESISTANCE TW107 Square 7 Brushed Stainl...

Страница 15: ...WARMER INSTALLATION INSTRUCTIONS N White 900mm L Black 900mm E Green 900mm N White 900mm L Black 900mm E Green 900mm CODE TUBE SHAPE BARS FINISH VOLTAGE AMPERAGE RESISTANCE TW001 Round 1 4 Polished St...

Страница 16: ...us warmup com I ca warmup com...