background image

Warmup One - Programmable Thermostat

EN -

 INSTALLATION INSTRUCTIONS

Installation

Safety Information

Technical Specifications

Step 1 - Identify Suitable Location

Step 2 - Installation and Wiring Connection

Before making any permanent fixtures Warmup recommends identifying your preferred location for the thermostat. It 

should be located in an area with good ventilation. It should not be beside a window/door, in direct sunlight or above 

another heat generating device (e.g. radiator or TV).

BATHROOM INSTALLATIONS: 

When installing the thermostat within a bathroom it MUST be mounted outside of Zone 2 

in accordance with Wiring Regulations. If it is not possible to identify a suitable location outside of Zone 2 within the 

bathroom, then it is recommended that the thermostat is installed in the adjacent room and set to control the heating 

by floor temperature only. When installed in this way, it is not possible to directly control the heating based on the 

room air temperature, only the floor surface temperature.

IMPORTANT INFORMATION: 

Installation should only be carried out by a qualified and competent electrician. The 

Warmup One requires a permanent power supply from a 30mA RCD protected circuit in accordance with the current 

edition of the Wiring Regulations. The thermostat and its power supply should be isolated from the mains supply 

throughout the installation process. Ensure that wires are fully inserted into the terminals, with no bare wire visible 

and secured. Any free strands should be trimmed, as they could otherwise cause a short-circuit.

• Operating Voltage - 

100 - 240 V AC 50/60 Hz

• Model - 

ONESTAT

• IP Rating - 

IP21

• Max. Load - 

16 A (3840 W) 

• Installation Depth - 

Min 35mm Pattress

• Dimensions - 

(H/W/D): 81 x 81 x 25 mm (from wall surface)

• Sensors - 

Air & Floor

• Compatibility - 

eUFH

• Sensor Type - 

2.5m NTC 100K (can be extended to 50 m)

• Er-P Class -

 

I

• Insulation Class - 

II

• Standards - 

EN60730-1 & EN60730-2-9

Gently press a flat head screwdriver 

into the plastic release clips 

highlighted above and pull face 

outwards, unclipping from the base. 

Place the frame and thermostat 

face somewhere safe.

Wire as shown above and install to 

a 35mm deep (min.) pattress

1 & 2:

 NTC100K Floor Sensor

(No Polarity)

3:

 PE - Supply and Load Earth

4: 

N1 - Load Neutral

6: 

N - Supply Neutral

5: 

L1 - Load Live

7: 

L - Supply Live

1

NTC 100K

SENSOR

PE

N1

L1

2

3

4

5

6

7

N

L

Floor Sensor

(No Polarity)

Heaters 

(Max. 16 Amps)

230V AC 

Supply

1

Warmup - IM - One - v1.0 2018-07-31.indd   1

31/07/2018   10:58:30

Содержание One

Страница 1: ...he Warmup One requires a permanent power supply from a 30mA RCD protected circuit in accordance with the current edition of the Wiring Regulations The thermostat and its power supply should be isolated from the mains supply throughout the installation process Ensure that wires are fully inserted into the terminals with no bare wire visible and secured Any free strands should be trimmed as they cou...

Страница 2: ...ating schedule mode is displayed ConF will flash PRESS OK to accept Failing to set the Heating Load correctly will reduce the accuracy of the thermostats air temperature reading To view current floor temperature when the thermostat is set to AF Air with floor limit PRESS and HOLD for 3 seconds Advanced Settings Troubleshooting Code Fault Action E1 Floor sensor short circuit in type F or AF Check t...

Страница 3: ... Schedule Setting a Heating Schedule allows you to set comfort temperatures at set times throughout the day The thermostat can bet set so that MON FRI 1 5 is programmed as a block with SAT 6 and SUN 7 programmed individually Alternatively the thermostat can set so that you program each day individually see advanced settings on how to switch between schedule settings Typically when setting a 6 peri...

Страница 4: ...o heating schedule mode PRESS OK Setting a Temporary Override Warmup warrants this product to be free from defects in the workmanship or materials under normal use and service for a period of 1 year from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective Warmup shall repair or replace it at Warmup s discretion If the product is ...

Страница 5: ...att de sitter ordentligt åtdragna Felaktig installation kan leda till kortslutning och brand Matningsspänning 100 240 V AC 50 60 Hz Modell ONESTAT IP Klass IP21 Maxbelastning 16 A 3840 W Installationsdjup Min 35mm Dimentioner H W D 81 x 81 x 25 mm Från vägg Sensor Luft och Golv Kompabilitet eUFH Sensortyp 2 5m NTC 100K Kan utökas till max 50 m Er P Klass I Issoleringsklass II Standard EN60730 1 EN...

Страница 6: ... för klocka visas ConF kommer blinka TRYCK OK för att acceptera Felaktig installning av termostatens belastning kan leda till felaktig temperaturdata För att se aktuellt temperaturvärde när termostaten är inställd på AF Luft och golv Tyck och HÅLL inne i 3 sekunder Avancerade inställningar Felsökning KOD Fel Action E1 Golvsensor kortsluten F eller AF Testa sensor och byt om skadad Mätvärde enligt ...

Страница 7: ...rläge Schemalagt läge Schemalagt läge låter dig välja olika temperaturer under dagen Termostaten kan ställas in till MÅN FRE 1 5 är programmerat som ett block med Lör 6 och Sön 7 programmerat som ett speparat Alternativt kan varje dag programeras separat se Avancerade inställningar Standardinställningen vid ett 6 periodsschema kommer period 1 3 coh 5 vara påslagen värme och period 2 4 och 6 kommer...

Страница 8: ...tt vanliga schema vid nästa periodstart för att avbryta avikande läge välj schemalagt läge och TRYCK OK Inställningar för tillfällig avvikelse Warmup garanterar att denna produkt är fri från defekter i utförande eller funktion under normal användning under en period av 1 år från inköpsdatum Om produkten på något sätt under garantiperioden är defekt ska Warmup reparera eller byta ut det Om produkte...

Отзывы: