Warmup One - Programmable Thermostat
EN -
INSTALLATION INSTRUCTIONS
Installation
Safety Information
Technical Specifications
Step 1 - Identify Suitable Location
Step 2 - Installation and Wiring Connection
Before making any permanent fixtures Warmup recommends identifying your preferred location for the thermostat. It
should be located in an area with good ventilation. It should not be beside a window/door, in direct sunlight or above
another heat generating device (e.g. radiator or TV).
BATHROOM INSTALLATIONS:
When installing the thermostat within a bathroom it MUST be mounted outside of Zone 2
in accordance with Wiring Regulations. If it is not possible to identify a suitable location outside of Zone 2 within the
bathroom, then it is recommended that the thermostat is installed in the adjacent room and set to control the heating
by floor temperature only. When installed in this way, it is not possible to directly control the heating based on the
room air temperature, only the floor surface temperature.
IMPORTANT INFORMATION:
Installation should only be carried out by a qualified and competent electrician. The
Warmup One requires a permanent power supply from a 30mA RCD protected circuit in accordance with the current
edition of the Wiring Regulations. The thermostat and its power supply should be isolated from the mains supply
throughout the installation process. Ensure that wires are fully inserted into the terminals, with no bare wire visible
and secured. Any free strands should be trimmed, as they could otherwise cause a short-circuit.
• Operating Voltage -
100 - 240 V AC 50/60 Hz
• Model -
ONESTAT
• IP Rating -
IP21
• Max. Load -
16 A (3840 W)
• Installation Depth -
Min 35mm Pattress
• Dimensions -
(H/W/D): 81 x 81 x 25 mm (from wall surface)
• Sensors -
Air & Floor
• Compatibility -
eUFH
• Sensor Type -
2.5m NTC 100K (can be extended to 50 m)
• Er-P Class -
I
• Insulation Class -
II
• Standards -
EN60730-1 & EN60730-2-9
Gently press a flat head screwdriver
into the plastic release clips
highlighted above and pull face
outwards, unclipping from the base.
Place the frame and thermostat
face somewhere safe.
Wire as shown above and install to
a 35mm deep (min.) pattress
1 & 2:
NTC100K Floor Sensor
(No Polarity)
3:
PE - Supply and Load Earth
4:
N1 - Load Neutral
6:
N - Supply Neutral
5:
L1 - Load Live
7:
L - Supply Live
1
NTC 100K
SENSOR
PE
N1
L1
2
3
4
5
6
7
N
L
Floor Sensor
(No Polarity)
Heaters
(Max. 16 Amps)
230V AC
Supply
1