Settings

The 4iE can be configured in different ways to suit you. The functions that can be accessed in the 
Settings menu include:

Time

Set time

manually set time (only available without WiFi connection)

Set date

manually set date (only available without WiFi connection)

Daylight savings

set daylight savings (only available without WiFi connection)

Heating preferences

Temperature format

choose celsius or 
farenheit

Control air/floor

use air or floor sensor as main measurement

Early Start

starts heating early so it’s up to temperature at the right time

Display/Audio

Background

change the screen background (upload your own on MyWarmup)

Home screen style

choose a theme for the main screen

Display brightness

change the screen brightness for normal use and standby

Lock

set a lock code and limits  for when the lock is active

Audio Feedback

turn the ‘click’ sound on or off

Network

Choose a WiFi network and enter the password if required

Fil Pilote

This is a feature specifically for France. You must also connect Fil Pilote to terminal 1

Master/Relay

This allows one thermostat to control another
1. 

Choose which thermostat is Master and which is Relay

2. 

Use low voltage cable to connect terminal 6 of both thermostats

3. 

Use low voltage cable to connect terminal 7 of both thermostats (in addition 
to floor sensor cables on the Master thermostat)

4. 

Set Relay thermostat to Relay mode first, then set the Master thermostat to 
Master mode

5. 

Program the Master thermostat. The Relay thermostat will no longer use its 
sensors, it will follow the Master thermostat

Gradual Start

Set the maximum temperature and time required to reach that temperature

Probes

Set the specification of the probes. You can also choose to hide the error message if you do not want to 
connect a probe

Probe application

Choose if the floor probe is being used as a Floor or Amb (ambient) sensor

Offset

Set the offset of the sensors to improve accuracy

Reset

This will restore all the factory default settings. You can also hold the button on the rear of the front 
module for 10 seconds to perform a system reset

Advanced settings

These options can affect the performance of your thermostat and should only be modified by an 
experienced professional or under the instruction of Warmup Technical Support

Heater settings

Heater limits

Set the temperature limits for your floor type. 

User Defined 

lets you set custom 

limits

Regulator

Regulator mode controls the heating in 10 minute cycles. The number you enter is 
the number of minutes in every 10 minute cycle that the heating will be on. This 
mode will not use the floor or air sensors for measurement

14

15

Содержание 4iE WiFi

Страница 1: ...ome is at the right temperature at the right time Energy monitoring Graphical display of your energy usage and cost with comparisons and forecasts WarmAppsTM Get apps on your 4iE like traffic alerts a...

Страница 2: ...the home screen To wake the 4iE just tap the screen or press Wake Hold the power button on the bottom of the device for 3 seconds to turn the thermostat on or off The icons at the bottom of the scree...

Страница 3: ...rocedure as below and you can set up a MyWarmup account at any time in the future Important Ensure you choose the correct System Type Electric underfloor Hydronic underfloor or Conventional central he...

Страница 4: ...mail you can connect your 4iE to the account Ensure your 4iE is connected to the internet If you see an error icon on the homescreen like below then your thermostat is not connected to the internet If...

Страница 5: ...re finished The programming works by setting Comfort Periods of warm temperatures shown with a green line Any time not covered by a Comfort Period will use a lower Setback temperature to save energy T...

Страница 6: ...til you raise the temperature again Preset Programs You can select a preset program schedule to get you started You can edit the program whenever you like by following the steps in Set Your Heating Pr...

Страница 7: ...f your system Press Energy Settings and select if you have a single rate tariff or a standard low energy tariff where you have a discounted cost during part of the day Enter your cost per KWH and rele...

Страница 8: ...stats 3 Use low voltage cable to connect terminal 7 of both thermostats in addition to floor sensor cables on the Master thermostat 4 Set Relay thermostat to Relay mode first then set the Master therm...

Страница 9: ...portant 8 Connect to 2nd wire of floor sensor colour not important Special Installation see numbering on diagram below Second sensor installation 2nd floor probe or exterior probe 6 Connect to 1st wir...

Страница 10: ...h latest IEE Wiring Regulations and appropriate Statutory Regulations Location The thermostat should be installed inside a single gang electrical wall box that is at least 30mm deep For optimal perfor...

Страница 11: ...ll not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals incorrect installation or damage which occurred while the product was in th...

Отзывы: