Reset
ProBEs
External sensor
You are able to attach a second sensor to terminals 2 and 3.
You can then use external sensor function to define the use of
that sensor:
1.
External sensor
: This is to be used when you can locate
the external sensor outside of the heated environment.
When this setting is selected it will display the external
temperature on the home screen and engage weather
compensation. Weather compensation saves energy by
delaying the start of heating period by 10 minutes if the
difference between internal and external temperature is
less than 41°F.
2.
2nd floor sensor
: This is to be used if the floor surface area is very large and delicate to overheating.
The reading from this secondary floor sensor will be used to monitor the overheat limit.
Probe specification
If you have already installed a sensor which was not supplied by Warmup then you can use this setting to
allow your thermostat to function. The possible options are NTC 10K (standard probe supplied by Warmup
with the 3IE), NTC 12K (probe supplied by Warmup with previous models of thermostat) and NTC 15K. Note
that all thermostats are different and Warmup can only validate the thermostat’s performance when used
with a Warmup probe supplied for use with the 3IE.
Offset
In order to improve temperature reading accuracy this feature allows you to bias each sensor’s temperature
reading up or down by 41°F.
Reset
Reset will restore all software settings to the factory specified defaults.
L
If you are experiencing problems with your thermostat then you can perform a system reset by
holding the button the rear of the front module for 10 seconds.