15 September 2017

 

 

All Dimension are in mm………….Copyright © 

 

8

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

FLUE HEIGHT MINIMUM DETAILS

 

The flue exit is to comply to ASNZS 2918: 2001

 

3D View

 

FRAME OUT - TRIM OUT DETAILS FOR FLUE SYSTEM

 

Note: FLUE SYSTEMS Casing….

 

Flue  system  may  require  to  be  Doubled  lined  to  comply. 

Ref ASNZS:2918:2001 4.3 Flue pipe casing

 

Note :

 

 

External Requirements

 

Refer to AS/NZS2918:2001 4.9.1

 

 

Install Flue system to AS/NZS2918:2001

 

 

When using a rubber or Bitumen flashing (Butynol, 

 

Dectite) an Additional Flue pipe Baffle is required.

 

 

All external air vents & ceiling penetrations must 

 

be bird proofed with permanently fixed screens.

 

 

All flashing to comply with E2.

 

FLASHING

TO COMPLY TO THE  BUILDING CODE (E2)

 

Note: ROOF FLASHINGS GENERAL:

 

Flashing  are  to  be  complaint  to  the  building  code  and 
the design will vary depending on the type of roof. 

 

  

Each installation is unique and your Installer will advise 
of the most appropriate flashing method to comply.

 

  

Содержание Tasman 46L Fire

Страница 1: ...ation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA SFAIT Installation Technician See www warmington co n...

Страница 2: ...CIENCY BURNING SOFTWOOD 66 Council Authorisation No Ecan 111359 Nelson 111359 When Tested in Accordance with AS NZS 4012 Performance may vary from tested values depending on actual operating condition...

Страница 3: ...d for most types of freestanding wood burners Check List Front Steel Baffle Vermiculite Board Baffle Brick Vermiculite Side Bricks X2 Check Door Seal Check Damper Control Serial Number Check Packed By...

Страница 4: ...s walls or surfaces Ref to ASNZS 2918 2001 3 2 1 The clearance to a Non Combustible wall or surface can be less that 100mm if a wet back is not fitted and no requirement for maintenance Construction o...

Страница 5: ...lite Board baffle brick in first on an angle through the door frame then repeat for the steel baffle Join the two parts together lift it up holding it horizontally resting on the one side bricks Fit b...

Страница 6: ...pproximate Note Before using the Fire with a Wet Back Fitted Consult your plumber for wet back system configurations and oper ation Wet back is to be fitted to an internal heat sync before use e g Hot...

Страница 7: ...be assembled with crimped ends down towards heater STAGE 7 Place Ceiling Plate over heater flue spigot ensuring the folded edge up stands are facing ceiling STAGE 8 From the roof lower Flue Pipes thr...

Страница 8: ...pipe casing Note External Requirements Refer to AS NZS2918 2001 4 9 1 Install Flue system to AS NZS2918 2001 When using a rubber or Bitumen flashing Butynol Dectite an Additional Flue pipe Baffle is...

Страница 9: ...oved outdoors immediately to a location clear of combustible materials 4 Cooking Because the top of the fire is in direct contact with the flame it offers a large cooking surface Ideal for entertainme...

Страница 10: ...Fire Contact with your local TA Territorial Authority to check for local compliance 11 Flue System The installation and construction of the flue system must comply with ASNZS 2918 The fire requires a...

Страница 11: ...mary on Setting High Temp Pain Read Stove Manufacturer instructions Babies small children pregnant women and pets should leave the area during the paint setting phase Ventilate well Paint surface will...

Страница 12: ...8 2001 and the appropriate Building codes The Flue system and Fireplace is to be swept annually or more frequently if required The Appliance and Flue System has been tested to ASNZS2918 2001 WARNINGS...

Отзывы: