background image

15 September 2017

 

 

All Dimension are in mm………….Copyright © 

 

6

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

Note:

 

Some  Wetbacks  can  NOT  be  fitted  to 
Fires  that  are  Installed  in  any  area  that 
falls under Clean Air Regulations .

 

Cut  Excess  BSP  Pipe  off  Wetback  to 
length if required…..By Plumber.

 

Description

 

 

 

70L

 

46L

 

Height from Bottom of Unit to Wetback Pipes

 

U

 

634

 

535

 

Height from Bottom of Unit to Wetback Pipes

 

V

 

709

 

610

 

Centre to Centre of Wetback Pipes

 

W

 

220

 

220

 

Power  Out

 

KW*

 

Wetback

 

-

 1.5

 

                   *Value is approximate”

 

Note: 

Before using the Fire with a Wet Back Fitted

 

Consult your plumber for wet back system configurations and oper-
ation.

 

Wet back is to be fitted to an internal heat

-

sync before use (e.g. Hot 

water cylinder / Radiator / Under floor heating etc…

 

 

WETBACK POSITION

 

SEISMIC RESTRAINT FIXING

 

Seismic Restraint Fixing Instructions

 

Fix    2X  Seismic  Restraints  through  the 
Hearth into the Floor . They are to  pen-
etrate  into  the  fixing  by  at  least  3  times 
their diameter.

 

Use  at  least  2  x  6  to  8  mm  Dia  Dyna 
Bolts or similar to fix fire to hearth and or 
through the hearth to the floor.

 

Fix  hearth  to  floor  with  appropriate    
adhesive , bolt or screw.

 

Ensure  that  the  Seismic  Restraint    
complies  with  ASNZS  2918:2001—   
Ref 3.8

 

Seismic restraint holes

 

on base of firebox legs

 

Tasman Series 

 

Wet Back

 

Содержание Tasman 46L Fire

Страница 1: ...ation details for the Warmington Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA SFAIT Installation Technician See www warmington co n...

Страница 2: ...CIENCY BURNING SOFTWOOD 66 Council Authorisation No Ecan 111359 Nelson 111359 When Tested in Accordance with AS NZS 4012 Performance may vary from tested values depending on actual operating condition...

Страница 3: ...d for most types of freestanding wood burners Check List Front Steel Baffle Vermiculite Board Baffle Brick Vermiculite Side Bricks X2 Check Door Seal Check Damper Control Serial Number Check Packed By...

Страница 4: ...s walls or surfaces Ref to ASNZS 2918 2001 3 2 1 The clearance to a Non Combustible wall or surface can be less that 100mm if a wet back is not fitted and no requirement for maintenance Construction o...

Страница 5: ...lite Board baffle brick in first on an angle through the door frame then repeat for the steel baffle Join the two parts together lift it up holding it horizontally resting on the one side bricks Fit b...

Страница 6: ...pproximate Note Before using the Fire with a Wet Back Fitted Consult your plumber for wet back system configurations and oper ation Wet back is to be fitted to an internal heat sync before use e g Hot...

Страница 7: ...be assembled with crimped ends down towards heater STAGE 7 Place Ceiling Plate over heater flue spigot ensuring the folded edge up stands are facing ceiling STAGE 8 From the roof lower Flue Pipes thr...

Страница 8: ...pipe casing Note External Requirements Refer to AS NZS2918 2001 4 9 1 Install Flue system to AS NZS2918 2001 When using a rubber or Bitumen flashing Butynol Dectite an Additional Flue pipe Baffle is...

Страница 9: ...oved outdoors immediately to a location clear of combustible materials 4 Cooking Because the top of the fire is in direct contact with the flame it offers a large cooking surface Ideal for entertainme...

Страница 10: ...Fire Contact with your local TA Territorial Authority to check for local compliance 11 Flue System The installation and construction of the flue system must comply with ASNZS 2918 The fire requires a...

Страница 11: ...mary on Setting High Temp Pain Read Stove Manufacturer instructions Babies small children pregnant women and pets should leave the area during the paint setting phase Ventilate well Paint surface will...

Страница 12: ...8 2001 and the appropriate Building codes The Flue system and Fireplace is to be swept annually or more frequently if required The Appliance and Flue System has been tested to ASNZS2918 2001 WARNINGS...

Отзывы: