Warmington SI 1100 Double Flue Скачать руководство пользователя страница 9

1 September 2016 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm………...Copyright on all products ©  

9

 

Diagram 

2:1 

Side 

Panel 

(No 

wings) 

Side 

Panel 

(No 

wings) 

Rivets 

20mm Air Gap at 
Bottom of Bottom 
Back Panel for 
Caitec Air Venting.  

Bottom Back Panel 

Top Back Panel 

Diagram 

1:1 

Step 2 : 

 

Rivet 2X Side Panels to pre assembled Back Panels as shown in 

2:1 , ensure the Top Flange on the Back Panel sits on the Side 
Panels creating a 20mm Air Gap at the bottom for the Caitec Air 
Venting .  

Step 4 :

 

Assemble Top Caps to Heatshield & secure in 

place with rivets as shown in diagram 4:1 . Install 

Flue Liners over S/S Flue’s

 

Step 3 : 

 

Install Firebox/Adaptor & secure in place , then 

Install first length of Flue’s with a Spacer’s at the 

Bottom , assemble Front Panel to Heatshield as 
shown in diagram 3:1 & secure in place by riveting 
as shown in 3:2 

Diagram 

4:1 

Cap 

Cap 

Step 1 : 

 

Assemble Top & Bottom Back Panel 

together by Riveting together at the 
centre as shown in diagram 1:1 . 
The Top Back Panel has a double 
Shield layer at the Top . 

HEAT SHIELD ASSEMBLY - FOR INSTALLATION INTO HEBEL HEAT CELL (NO FASCIA KIT)

 

Heat Shield Check List

 

Front Panel

 

 

 

Back Panel

 

 

 

Side Panel LH

 

 

 

Side Panel RH

 

 

 

Top Cap LH

 

 

 

Top Cap RH

 

 

 

Packed By

 

 

 

Front Panel 

Diagram 

3:2 

Diagram 

3:1 

Front Panel 

Rivets 

Rivets 

Top Flange 

This is the Rear View . 
Turn around to Assemble 
to the Side Panels 

Rivets 

Содержание SI 1100 Double Flue

Страница 1: ...gton Fire Installation The Warmington unit is to be Installed by a Certified Warmington Installer or a Certified NZHHA Installation Technician See www homeheat co nz members for a Certified NZHHA SFAI...

Страница 2: ...w the wind will interact with the fire and flue system Care needs to be taken to ensure that the flue termination is in the correct position to maximise performance The Prevailing Wind Care needs to b...

Страница 3: ...Peak 30 Range 14 Estimated unless stated otherwise WARMINGTON FIREBOX DIMENSION FIREBOX HEAT SHIELD CABINET Adaptor Fitting Seal Adaptor to Firebox using High temp Gasket Sealant Bolt through holes pr...

Страница 4: ...ir from an external air source to ensure that the open fire has pre heated combustion air maximising efficiency while maintaining the home at constant pressure equilibrium reducing the risk of back dr...

Страница 5: ...50 Heat Cell Clearance Depth P 610 Heat Cell Clearance Height Q 2203 Hearth Width R 1550 Hearth Projection S 650 Window Height V 1000 Window Width W 1350 Chimney Chase Clearance X 450 Chimney Chase Cl...

Страница 6: ...0 Plinth Width T 1350 Plinth Depth U 610 Centre of Flue J 338 Chimney Chase Clearance X 450 Chimney Chase Clearance Y 1000 TIMBER PLAN FRONT ELEVATION CROSS SECTION BLOCK PLAN FRONT ELEVATION CROSS SE...

Страница 7: ...se Firebox SI 1100 DF Heat cell Clearance Width OO 1210 Heat Cell Clearance Depth PP 700 Heat Cell Clearance Height QQ 2390 Hearth Width RR 1550 Hearth Projection SS 650 Window Height VV 810 Window Wi...

Страница 8: ...ote If plastering the Heat Cell structure it is recommended to use a fibreglass mesh with a latex plaster to minimise the chance of the plaster cracking See your plasterer for correct materials and ap...

Страница 9: ...ld secure in place with rivets as shown in diagram 4 1 Install Flue Liners over S S Flue s Step 3 Install Firebox Adaptor secure in place then Install first length of Flue s with a Spacer s at the Bot...

Страница 10: ...Promina Fascia Kit List Tick Promina Top Panel 1 Promina LH Side Panel 1 Promina RH Side Panel 1 Joining Plate 2 Bolts Nuts 8 Wings 2 Lintel Cap 1 Packed By Step 5 Assemble Front Panel to Heat Shield...

Страница 11: ...m 3 2 Front Panel Diagram 3 1 Front Panel Diagram 2 1 Side Panel No wings Side Panel No wings 20mm Air Gap at Bottom of Bottom Back Panel for Caitec Air Venting Top Flange Diagram 4 1 Cap Cap HEAT SHI...

Страница 12: ...op Spider into position ensure that the legs of the spider are fitted inside the liner and that the spider is positioned hard down onto the liner and tighten with the screw and nut 3 Place the Flashin...

Страница 13: ...ng Butynol Dectite an Additional Flue pipe Baffle is required All external air vents ceiling penetrations must be bird proofed with permanently fixed screens All flashing to comply with E2 Test Report...

Страница 14: ...E VENTING THROUGH FLASHING No Insulation under flashing Insulation under flashing CHIMNEY CHASE FLASHING DETAILS SETTING ADD COWL AND FLASHING CONE HEIGHT Note Flashing Spigot height is determined by...

Страница 15: ...ion are in mm Copyright on all products 15 FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue ex...

Страница 16: ...ification All Dimension are in mm Copyright on all products 16 COMBUSTIBLE MANTLE CLEARANCES HEARTH CLEARANCES Note For Combustible Floors Minimum Hearth of 380mm A must be maintained When Raising can...

Страница 17: ...nths on the firebox from original date of purchase WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4...

Отзывы: