
29 March 2021
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm
………….
Copyright ©
19
ADJUSTMENT OF HI / LOW PRESSURE
-
SG ONLY
Adjusted by Gasfitter ONLY
ADJUSTMENT OF THE PILOT
-
3 FLAME for BOTH SG & EG Adjusted by Gasfitter ONLY
Note: Control Valves are factory set but may require adjustment onsite
•
Turn Appliance off & remove front plastic cover on Igniter. Pull cover to slide off.
•
Unscrew test nipple on the burner manifold & fit the test gauge securely
-
see diagram.
•
To set the High:
Light the burner & turn to high
-
then adjust the high screw to the desired pressure
-
see spec
’
s.
•
To set the Low:
Light the burner & turn to low
-
then adjust the low screw to the desired pressure
-
see spec
’
s.
•
Extinguish Appliance, remove test equipment and secure test nipple.
•
Check valve & burner for correct operation & check fire for gas leaks.
Note:
When the base screw is removed, gas will leak from the out let, ensure that the pilot is
not adjusted or the screw is removed when the fire is burning.
•
Adjustment of Pilot
-
3 Flame: Unscrew base screw as shown in Diagram 2.
•
Insert a screwdriver as shown in Diagram 3 and adjust the adjustment screw up inside
the 3 Flame Pilot to adjust the flame height.
•
The flame must always be passing over the Electrodes &/or File Tube on either side.
•
Replace the Base screw and check for leaks.
3 Flame Pilot in
assembled state
Correct operation of
3 Flame Pilot
3
2
Note: to Gasfitters
The 3 flame pilot may need adjustment
after a period of running time on set up
as the increase in heat in the fire will
induce a higher draft in the fire, and
may pull in flame away from the File
Tube causing the fire to shut down.