Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

All Dimension are in mm

 

3

 

HEARTH CLEARANCES

 

Note: For Combustible Floors

 

 

Minimum Hearth of 300mm  (H) must be 

maintained at any given height.

 

 

Burner

 

 

 

SG

 

780 TWIN

 

SG

 

900 TWIN

 

SG

 

1100 TWIN

 

SG

 

700 TWIN

 

SG

 

600 TWIN

 

Burner Width

 

A

 

754 

874 

1074 

674 

555 

Burner Height

 

B

 

205 

205 

205 

205 

205 

Burner Depth

 

C

 

500 

500 

500 

500 

500 

Flue Diameter min.

 

J

 

200 

250 

250 

200 

150 

Flue CSA mm

 

K

 

31 416 

49 088 

49 088 

31 416 

17 671 

WARMINGTON BURNERS

 

IMPORTANT NOTES : 

 

* Inlet Pressure not to exceed 4.0kPa

 

GAS SPECIFICATIONS                  Tested to current gas standards

 

NOTE : All Test Pressures are tested by a Independent Test Lab

 

MODLE

 

SG

-

EG 780 Twin

 

SG

-

EG 900 Twin

 

SG

-

EG 1100 Twin

 

SG

-

EG 700 Twin

 

SG

-

EG 600 Twin

 

LPG

 

 

 

 

 

 

Nominal Pressure kPa

 

2.75 kPa

 

2.75 kPa

 

2.75 kPa

 

2.75 kPa

 

2.75 kPa

 

Nominal Injector Size mm

 

4 X 1.1mm

 

4 X 1.2mm

 

4 X 1.3mm

 

4 X 1.0mm

 

4 X 1.0mm

 

Max Supply Pressure kPa

 

3.0

 

3.0

 

3.0

 

3.0

 

3.0

 

Min Supply Pressure kPa

 

2.5

 

2.5

 

2.5

 

2.5

 

2.0

 

Burner Pressure High kPa

 

2.5

 

2.5

 

2.3

 

2.5

 

2.0

 

Burner Pressure Low kPa

 

0.75

 

0.75

 

0.75

 

0.75

 

0.75

 

MJ/h

 

59

 

72

 

76

 

50

 

42

 

Flame Effect Output Only

 

Effect

 

Effect

 

Effect

 

Effect

 

Effect

 

Supply Pipe Size dia—min

 

1/2”

 

1/2”

 

1/2”

 

1/2”

 

1/2”

 

Natural Gas

 

 

 

 

 

 

 

 

 

Nominal Pressure kPa

 

1.5 kPa

 

1.5 kPa

 

2 kPa

 

1.5 kPa

 

1.5 kPa

 

Nominal Injector Size mm

 

4 X 1.9mm

 

4 X 2.2mm

 

4 X 2.4mm

 

4 X TBC

 

4 X TBC

 

Max Supply Pressure kPa

 

3.0

 

3.0

 

3.0

 

3.0

 

3.0

 

Min Supply Pressure kPa

 

1.0

 

1.0

 

1.5

 

1.0

 

1.0

 

Burner Pressure High kPa

 

0.85

 

0.6

 

0.5

 

TBC

 

TBC

 

Burner Pressure Low kPa

 

0.2

 

0.1

 

0.1

 

TBC

 

TBC

 

MJ/h

 

70

 

77

 

83

 

TBC

 

TBC

 

Flame Effect Output Only

 

Effect

 

Effect

 

Effect

 

Effect

 

Effect

 

Supply Pipe Size dia—min

 

1/2”

 

1/2”

 

1/2”

 

1/2”

 

1/2”

 

Lab. Test No

 

WAR0112

 

TBC

 

GL 939

 

GL 945

 

GL 931

 

Lab. Test Dates

 

30/05/2017

 

TBC

 

June 2010

 

July 2010

 

30/05/2010

 

H

 

Содержание SG-EG 1100 Twin

Страница 1: ...tified Warmington installer or an approved NZHHA installation technician See www homeheat co nz members for a certified NZHHA SFAIT Installer in your area A licenced certified gas fitter and licenced...

Страница 2: ...from inside the building to the outside A lower pressure in the building may induce a draft down the flue system and back into the building causing the fire to smoke or spill into the building Care n...

Страница 3: ...win LPG Nominal Pressure kPa 2 75 kPa 2 75 kPa 2 75 kPa 2 75 kPa 2 75 kPa Nominal Injector Size mm 4 X 1 1mm 4 X 1 2mm 4 X 1 3mm 4 X 1 0mm 4 X 1 0mm Max Supply Pressure kPa 3 0 3 0 3 0 3 0 3 0 Min Sup...

Страница 4: ...the Data Plate is correct for the available supply LPG or NG A Copper Gas supply capable of supplying the correct MJ h should be brought into the rear of the Installation Cavity through the hole prov...

Страница 5: ...als onto the Bottom Row Each Coal randomly positioned with the Torn roughest Face Outward Ensure Coal positioning does not directly block the 3 Flame Pilot The placement of the Coals Logs may vary to...

Страница 6: ...Dimension are in mm 6 SG 600 700 780 900 1100 twin burner Burner Only Installation Guide Only Traditional Classic Grate Pure Grate Installation to comply with current standards When installing a fitte...

Страница 7: ...ng the Switch in a Depressed State repeat steps 2 3 if neces sary Once the Pilot Flame is lit hold this position for 3 5 seconds release from the Depressed State before setting the Flame Control to Fu...

Страница 8: ...ire for Gas Leaks Adjustment of High Low Settings Must be Carried out by a Certified Gas Fitter Only ADJUSTMENT OF THE PILOT 3 FLAME BOTH SG EG Only to be Adjusted by Gasfitter Note When the Base scre...

Страница 9: ...nsion are in mm 9 EG On Off 600 700 780 900 1100 twin burner Burner Only Installation Guide Only Traditional Classic Grate Pure Grate NOTE IMPORTANT INFORMATION FROM THE STANDARD Installation to compl...

Страница 10: ...kPa value in the Table for maximum output NOTE If setting the Pressure is required it is to be carried out by a Certified Gas Fitter If adjustments are necessary remove the dust cap on the control val...

Страница 11: ...pat tern and glow During the Initial Burning in period some smoke and smell may be experienced the appliance should be run in a well ventilated room until these dissipate Test Point Inlet Modulator Ha...

Страница 12: ...ch 2021 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm 12 ON OFF SWITCH SIT 840 WIRING D...

Страница 13: ...nsion are in mm 13 EG Hi Low 600 700 780 900 1100 twin burner Burner Only Installation Guide Only Traditional Classic Grate Pure Grate NOTE IMPORTANT INFORMATION FROM THE STANDARD Installation to comp...

Страница 14: ...e NOTE If setting the Pressure is required it is to be carried out by a Certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment Screw and Nut are on the Front Side of...

Страница 15: ...e their full flame pattern and glow During the Initial Burning in period some smoke and smell may be experienced the appliance should be run on the high position in a well ventilated room until these...

Страница 16: ...h 2021 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm 16 HIGH LOW SWITCH SIT 845 WIRING...

Страница 17: ...on are in mm 17 EG with remote 600 700 780 900 1100 twin burner Burner Only Installation Guide Only Traditional Classic Grate Pure Grate NOTE IMPORTANT INFORMATION FROM THE STANDARD Installation to co...

Страница 18: ...ccept The days of the week will begin to flash Setting the day of the week function Press and release the or button to change the day of the week to the following or previous day Press and hold the or...

Страница 19: ...of the week press OK First period s start time The display will indicate P1 on the top The Hour and AM PM settings will now flash To set the P1 starting time Press and release the or button to increa...

Страница 20: ...le Play Store https play google com store apps details id com millec intelligythermostatmkii For instructions on how to push the appliance to your Wi Fi please go to the Warmington website and find de...

Страница 21: ...nite first and once this is on it will ignite the main burner Pressing and releasing the power button again will switch off the appliance When the appliance is turned on the gas fire will be set to me...

Страница 22: ...essure is required it is to be carried out by a Certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment Screw and Nut are on the Front Side of the Gas Control Valve sh...

Страница 23: ...lame pattern and glow During the Initial Burning in period some smoke and smell may be experienced the appliance should be run on the high position in a well ventilated room until these dissipate DIAG...

Страница 24: ...2021 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification All Dimension are in mm 24 FULLY MODULATING SIT 845 WIRING...

Страница 25: ...rve the following precautions associated with any heating appliance or open fire Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build up of hazardous ga...

Страница 26: ...serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING A...

Отзывы: