PROCEDURE FOR THE TEST AND COMISSIONING OF YOUR DECORATIVE BURNER
Ensure Gas Supply and the Power Supply (caution 240V) to the Unit.
•
Refer to Data Plate on this Specification for settings. The Data Plate is attached to the under carriage of
the Burner .
•
Loosen the Jet Test point and attach manometer (Digital is preferred). The Test Point is on the Right
Hand Side of the Gas Burner , as Shown Below .
•
Light Appliance and check the pressure to the Hi kPa value in the Table for maximum output.
NOTE : If setting the Pressure is required it is to be carried out by a Certified Gas Fitter.
•
If adjustments are necessary, remove the dust cap on the control value. The Pressure Adjustment Screw
is on the Front Side of the Gas Control Valve (shown in Diagram
B
in this specification) and are
Factory
set.
Pressure Setting: Set the pressure to the Hi kPa value in the table for maximum output. The burner will
operate any pressure between the hi and the low pressures.
Pressure Setting
: Turn the Burner on with the switch and wait for full ignition. Screw the adjusting screw clock-
wise to Increase the Outlet Pressure or screw counter clockwise to Decrease the Pressure to the desired set-
tings . Use a standard screw driver.
WARNING:
Ensure that the dust cap is replaced after adjustment