background image

14 June 2016 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. 

All Dimension are in mm……..Copyright ©  

FLUELESS OUTDOOR GAS OPEN FIRES 

Installation Instructions

 

SG & EG 700-780-900-1100-1250-1500

 

Outdoor Flueless

 

IMPORTANT NOTE:  
 
ALL WARMINGTON FLUELESS 
GAS FIRES ARE TO BE REBATED 
INTO ITS ENCLOSURE 40mm IF 
EXPOSED TO DIRECT 

Important Note:

 

Fire for Outdoor use only, 
NOT to be Installed Indoors . 

ALL WARMINGTON FLUELESS GAS 
FIRES ARE TO BE INSTALLED INTO 
OPEN OUTDOOR AREAS ONLY, 
THIS IS TO ALLOW GASSES TO ES-
CAPE.  

All  Load  Bearing  Structures  are 
to be Engineered to carry load . 
See table for weights in kg 

Note: HEBEL KITSET ASSEMBLY 

Details 

 

When purchasing the “Hebel Heat Cell Kit” the 

assembly Guide will come with the Kit. 
 

These  Hebel  Kits  are  not  designed  to  carry 
loads .

 

Plinth & Hearth 
NOT Provided 

The fireplace is constructed and tested to comply with NZS 4558(int):2013 “Decorative gas log and other fuel effect appliances”. 

 

Keep these instructions for further reference. Ensure that you have the correct and current installation details for the Warmington fireplace. 

 

Installation

 

The Warmington unit is to be installed by a certified Warmington installer or an approved NZHHA installation technician. 

See www.homeheat.co.nz/members for a certified NZHHA SFAIT Installer in your area. 

A licenced certified gas fitter and licenced electrician are required to run power and gas supplies as required to the unit and any commissioning as part of the 

installation process.The heater must be installed according to these instructions and in compliance with all relevant building, gas fitting, electrical and other 

statutory regulations. 

 

IMPORTANT 

Read all the instructions carefully before commencing the Installation. Failure to follow these instructions may result in a fire hazard and void the warranty 

Related documents 

Fireplace installation, and instructions to comply with NZS 5601.1:2013, 3645.1(Int):2010, 

3645.2(Int):2010, 5266:2014, 2918:2001. 

Содержание SG 700

Страница 1: ...and tested to comply with NZS 4558 int 2013 Decorative gas log and other fuel effect appliances Keep these instructions for further reference Ensure that you have the correct and current installation...

Страница 2: ...TIFIED GASFITTER OR CERTFIED NZHHA SFAIT INSTALLER WHAT S SUPPLIED WHEN ORDERED LEAVE MANUAL WITH THE CUSTOMER ONCE INSTALLED INSTALLER OWNER PLEASE KEEP THESE SPECIFICATIONS FOR FUTURE REFERENCE Supp...

Страница 3: ...x 100mm Vents should be fitted 1 at the Top of the alcove and 1 at the base of the Alcove to allow air flow Note Clean and touch up paint on the fire and cover if necessary Stage 3 Finishing Procedur...

Страница 4: ...th H 395 395 395 395 395 395 Fascia Width L 1060 1260 1410 1560 940 860 Fascia Height M 680 680 680 680 680 680 Fascia Section N 80 80 80 80 80 80 Hearth Width O 1100 1180 1300 1500 1550 1800 Hearth P...

Страница 5: ...ase and at the Top Hebel Cell Firebox Fiberglass Reinforced Mesh 2mm Non Combustible Latex Based Plaster Water Proof Non Combustible Important Note NO Combustible Material to be used below the measure...

Страница 6: ...kPa 2 75 kPa 2 75 kPa 2 75 kPa 2 75 kPa Nominal Injector Size mm 2 X 1 3mm 2 X 1 4mm 4 X 1 1mm 4 x 1 2mm 2 X 1 2mm 2 X 1 1mm Burner Pressure High Kpa 2 5 2 5 2 5 2 5 2 5 2 5 Burner Pressure Low Kpa 0...

Страница 7: ...LINTH CONSTRUCTION DETAILS Note If Solid Plastering the Heat Cell Structure it is recommended to use a Fibreglass Mesh with a Latex Based Plaster to minimise the chance of the Solid Plaster cracking S...

Страница 8: ...600 600 Heat Cell Clearance width J 1210 1210 1210 1610 1610 1610 Heat Sensitive Zone R 1700 1700 1700 1700 1700 1700 IMPORTANT NOTE ALL WARMINGTON FLUELESS GAS FIRES ARE TO BE REBATED INTO ITS ENCLOS...

Страница 9: ...o change product specifications without prior notification All Dimension are in mm Copyright 9 GAS SUPPLY ELECTRONICS LOCATION Firebox SG EG 700 SG EG 780 SG EG 900 SG EG 1100 SG EG 1250 SG EG 1500 Fr...

Страница 10: ...r of the Installation Cavity through the hole provided A Flare Nut is provided on the Burner for Gas Connection to the Appliance TO THE INSTALLER GAS FITTER ELECTRICIAN FITMENT OF BURNER Burner may be...

Страница 11: ...ttered to achieve best Visual Effect Fit Burner Grate by sliding R L Side Metal Pins on Grate into Holes Located on Burner Side Plates as shown below 2 Top Row Slide R LH Grate Pins into Holes located...

Страница 12: ...o light all the way across Once the flame is established adjust to the desired setting and close the cover To shut down Open the cover by pulling it outwards Turn the control ignition switch to PILOT...

Страница 13: ...e Control Valves are Factory Set but may require adjustment onsite Turn Appliance Off Remove Front Plastic Cover on Igniter Pull Cover to Slide off Unscrew Test Nipple on the Burner Manifold fit the T...

Страница 14: ...bserve the following precautions associated with any heating appliance or open fire Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build up of hazardous...

Страница 15: ...s Switched Off due to Power Failure In the circumstance of a Power Failure the Remote Control System will return to the default settings which is a Low Flame and the Fan Turned Off If the Gas Fails to...

Страница 16: ...the Power LED will start flashing and after 30 minutes the appliance will Shut Off Automatically By pressing the Timer Button again within the 30 minute period this will reset the Timer and the power...

Страница 17: ...TE If setting the Pressure is required it is to be carried out by a certified Gas Fitter If adjustments are necessary remove the cap The Pressure Adjustment Screw and Nut are on the Front Side of the...

Страница 18: ...fied that the Appliance is working correctly fit the Front Panel Assembly back to the Gas Burner NOTE Ensure you peel the Protective Plastic Coating from any Stainless Steel components if fitted All B...

Страница 19: ...nd LTD reserves the right to change product specifications without prior notification All Dimension are in mm Copyright 19 REMOTE IGNITION EG GAS FIRE WIRING DIAGRAM Modulator Harness Connections Note...

Страница 20: ...t be serviced annually and any service operation must be carried out by a qualified service person WARNINGS WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTI...

Отзывы: