Warming-Trends.com | 303 346 2224 | [email protected]
13
6.2
Identify the flared fitting that comes on the end of your flex line. There should be two total. Unscrew the flared fitting
from the flex line, then apply thread sealant to the non-flared end of the fitting
{See Photo 19}
and screw into the “IN”
side of the valve. Tighten with a wrench to avoid leaks.
{See Photo 20}
6.3
Screw the flex line onto the flared end of the flared fitting that is attached to the valve. Do not use thread sealant.
Tighten with a wrench to avoid leaks.
{See Photo 21}
6.4
Apply thread sealant to the non-flared end of the second flared fitting and screw into one side of the provided key
valve using thread sealant. Tighten with a wrench to avoid leaks.
{See Photo 22}
6.5
Mount the key valve and escutcheon plate to your fire pit, and then take the other end of the flex line and screw it
into the flared end of the flared fitting on the key valve, connecting the key valve to the Platinum Valve. Do not use
thread sealant. Tighten with a wrench to avoid leaks.
{See Photo 23}
The other end of the key valve will then connect
to your gas supply.
Photo 19: Flared Fitting with Thread Sealant
Photo 20: Connecting the Flared Fitting to the Platinum Valve
Photo 21: Attaching the Flex Line
Photo 22: Connecting the Flared Fitting to the Key Valve
Photo 23: Connecting the Flex Line from the Platinum Valve to the Key Valve
Flared End (No thread sealant)
Non-Flared End
Thread Sealant
Gas Supply
Fire Pit
Flex Line leading to the
Platinum Valve