21
Failure
Code
Failure / Error Definition
Possible Reasons
Combi Status / Solution
E 09
Waterless operation in the radiator system
Water leakage in the installation line or combi
Consult the authorized installer and/or authorized
service.
E 10
AUX Output Sensor failure
Sensor failure
Call the authorized service in case of repeated
after reset. (1)
E 16
AUX Return Sensor failure
Sensor failure
Call the authorized service in case of repeated
after reset. (1)
E 11
Gas valve modulator connection is broken
Internal failure
Call the authorized service in case of repeated
after reset. (1)
E 17
Maximum difference failure between 2 NTC
temperature sensors
Inadequate circulation
Call the authorized service and installer in case of
repeated after reset. (1)
E 19
WFS selection with read entrance flow meter
Internal failure
Call the authorized service in case of repeated
after reset. (1)
rE 28
Maximum locking number reached
Usable RESET number reached.
Warning: Failure can be reset successively for
maximum 5 times, then function is terminated for
at least one hour and one try is possible per hour
provided that having maximum 5 tries combi is
reset.
E 37
Low voltage failure
Seen when the voltage required for operation
of combi is under envisaged limits.
Combi starts again without requiring RESET after
the Electrical voltage turns into normal conditions.
E 40
Electricity network frequency error
Fluctuation in electricity frequency
Call the authorized service in case of repeated
after reset. (1)
rE 41
Flame loss after 6 successive ignitions.
Control whether gas supply line valves are
open. Respectively, control whether gas valves
of your combi, home and building are open
.
Call the authorized service in case of repeated
after reset. (1)
E 42
Failure in pushbuttons
Button failure
Call the authorized service. (1)
E 43
Room thermostat (OT) communication failure
Disconnection or communication loss in room
thermostat connection
Call the authorized service. (1)
rE 44
Failure of exceeding the gas valve opening
period without flame
Occurs when the gas valve remains open lon-
ger than expected, combi continues operating
for normal functioning.
Press the RESET button. (1)
E 62
Calibration request
Electronic brain detects absence of calibration.
Control when electronic card is replaced or
will be required for changing an air and gas
variation in parameters section.
It ends when calibration is completed.
rE 72
Delta T error due to failing to ignite
Gas line valves are closed or flue problem
Ensure that gas line valves are open and control
flue pulse/circulation. (1)
E 74
Second CH Temperature
Sensor failure
Call the authorized service. (1)
rE 80
Gas valve failure
Internal failure
Call the authorized service. (1)
rE 81
İgnition problem at first start (1, 2)
Problem in the flue line
Call the authorized service. (1)
rE 82
Burning problem failure
Problem in the flue line
Call the authorized service. (1)
E 83
Temporary mis-burning failure
Gas pressure and/or flue line problem
Have the gas pressure and flue line controlled. (1)
rE 88
Failure in gas line cycle
A failure is detected in gas valve components.
Combi is not functioning (1).
rE 98
Electronic card start (first start) failure
Internal failure
Call the authorized service. (1)
rE 99
General failure
An error i detected in the combi.
Press the RESET button. (1)
(1) Call the Authorized Service if failure continues.
(2) 81 numbered failure corresponds any blocking in the exhaust gas
pipe. In such case, you should consult the authorized service technician
before re-starting the combi.