NOTICE:

 Customer is solely responsible for determining whether the prod-

ucts and the information contained in this installation guide are appropriate 
for Customer’s use and are in compliance with applicable laws because the 
applicable laws related to the installation and use of this product may vary 
from one location to another and may change with time.  Customer rep-
resents and warrants that Customer is required to check current local laws, 
building codes and other local requirements and that all local requirements 
will be adhered to in connection with the installation of this product.  
NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE 
WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY WARMBOARD.  ALL 
IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.  
FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING TO MANU-
FACTURER’S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES.  
IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS NOT RESPONSI-
BLE FOR ANY CONSEQUENTIAL OR OTHER DAMAGES THAT MAY ARISE 
FROM USING WARMBOARD PRODUCTS OR COMPONENTS.
Warmboard assumes no obligation or liability for the information contained 
in this document.  The Customer assumes all risks as to the use of this 
product.  Customer’s exclusive remedy or any claim (including any claim 
for negligence, strict liability, or tort, without limitation) shall be limited 
to the warranty coverage expressly provided in Warmboard’s warranty 
documents.  Failure to stringently adhere to any of the recommended pro-
cedures of this installation guide and/or any other Warmboard document 
related to this product shall release Warmboard of all liability with respect 
to this product or the use thereof. 
For complete warranty information please call 1.800.556.0595  
or visit warmboard.com
KEEP OUT OF REACH OF CHILDREN

Содержание Warmsource

Страница 1: ...For use with Warmsource and Warmsource Flex natural gas boiler Warmsource and Warmsource Flex propane gas boiler WARMBOARD COMFORT SYSTEM 0622 Installation Guide...

Страница 2: ...no programming or commissioning and water temperatures are calibrated using our Indoor Reset algorithm 7 DO NOT adjust any boiler settings without consulting Warmboard Changes made through the boiler...

Страница 3: ...S f Install tubing some loops before walls and use the provided labels to keep track of loops and zones f Frame walls roof sheeting f Install tubing manifolds some loops f Install all 110 volt electri...

Страница 4: ...up water for evaporation f Backflow preventer required by code in many jurisdictions it prevents water in the closed loop system from mixing with the domestic water f 11 4 combo ball valve hose bib f...

Страница 5: ...3 48 2 121 4 2 281 2 33 27 33 121 2 Pressure Relief Valve Mounting Bracket Air Vent r Exhaust Air Intake ensate right Gas right Supply back Return front 9 43 8 3 48 9 43 8 3 48 2 121 4 2 281 2 33 27...

Страница 6: ...5 81 2 21 4 151 2 51 2 91 4 110K 150K 199K 171 2 11 2 199K 150K 23 4 91 4 113 4 121 2 151 4 21 2 91 4 111 4 13 16 21 4 151 2 171 2 Bottom View 80K Top View 80K 80K 5 81 2 21 4 151 2 11 2 51 2 91 4 110...

Страница 7: ...depicts the space necessary for piping and mechanical components The minimum depth is 40 for access and serviceability Electrical Requirements f Warmsource boiler 160W Warmsource pump 30 165W varies...

Страница 8: ...res two individuals to move safely Connections f Connect the PVC intake and exhaust lines gas line condensation discharge line and pressure relief discharge line per the Lochnivar Noble Manual f Plumb...

Страница 9: ...er field supplied 9 17 24 2 Supply back Return front Mounting Bracket 43 8 Pressure Relief Valve Air Vent Air Exhaust Air Intake Condensate Gas 1 11 4 Copper field supplied 9 17 24 2 Supply back Retur...

Страница 10: ...8 18 121 2 151 4 21 4 151 2 11 2 17 80K 80K 23 4 5 9 110K 23 4 15 150K 23 4 91 4 113 4 18 18 121 2 151 4 5 81 2 17 21 4 151 2 11 2 41 4 81 2 17 43 4 81 2 80K 199K 150K 23 4 91 4 113 4 18 18 18 121 2 1...

Страница 11: ...ecessary for piping and mechanical components The minimum depth is 40 for access and serviceability Electrical Requirements f Warmsource boiler 160W Warmsource pump 30 165W varies by heat load Smart R...

Страница 12: ...ure relief discharge line per the Lochnivar Noble Manual f Plumb the cold water line to the backflow preventer and the pressure reducing valve WCS Design Drawings f Plumb Warmsource Flex to the boiler...

Страница 13: ...filling the system with water for 10 15 minutes until air cannot be seen or heard escaping the hose f Close the fast fill lever then slowly close hose bib A f Manifold 1 is now complete Repeat this pr...

Страница 14: ...Warmsource will reach the target temperature in about 10 minutes f Step 4 Return to each manifold and adjust the flow rates of each loop 1 Unthread and discard the white caps from the return side of t...

Страница 15: ...ur WCS Design Drawings Controls Warmboard Controls consist of the following f 110 volt thermostats one per heating zone f 110 volt Manifold Controller one per manifold f 24 volt solenoid valve loop ac...

Страница 16: ...to behave inaccurately If there are any discrepancies regarding the thermostat or zoning contact us immediately f Remove the appropriate thermostat from the box f Grip the face of the thermostat on th...

Страница 17: ...inal connection AC1 Fan on the Smart Reset Controller SRC f Connect the wires from the AC unit to the terminal block accordingly RC 24v power red wire Y Cooling Call yellow wire G Fan green wire f To...

Страница 18: ...nutes the green lights will turn blue indicating that the actuators have opened and water is flowing to the zone f If something does not appear to be working properly consult your Warmboard Engineered...

Страница 19: ...EXCLUDED FAILURE TO INSTALL WARMBOARD PRODUCTS ACCORDING TO MANU FACTURER S INSTRUCTIONS WILL VOID ALL APPLICABLE WARRANTIES IT IS EXPRESSLY UNDERSTOOD THAT WARMBOARD IS NOT RESPONSI BLE FOR ANY CONSE...

Отзывы: