WAREMA Quatronic dialog
®
Operating instructions
Runtime UP
TurnTime
Setting: DOWN
TurnTime
Select the desired parameter by pressing the
or
button.
Example
Run time for the UP command (
UP
)
In this menu, you can change the settings for each facade (
F1
-
F4
) using the
/
buttons.
Runtime UP
2:30 2:30 2:20 1:00
(Min:Sec) CH1 CH2 CH3 CH4
The
OFF
setting is achieved by setting the value to
00:00
. The word
OFF
ap-
pears instead of
00:00
. This switches off the time switch control at the re-
spective facade.
Leave the menu after completing the entries using the
disp/prog
button.
This saves the changes you made.
8.2.2 Run time AP/ OWA
The move command is active for the set run time, which means that if the run
time is too short, the sun shading product does not move all the way to the
limit position.
By setting the DOWN run time accordingly, you can obtain a light band (i.e.
the sun shading product does not move all the way down to the lower limit
position).
Ideally, the set run time is identical to the actual run time of the sun shading
product.
A run time of
99:59
minutes is equivalent to a continuous command.
CONTINUOUS
appears in the display instead.
A run time of
00:00
is equivalent to a jog mode, i.e. when a move command
is triggered, the sun shading product only moves as long as the arrow key is
activated.
OFF
appears in the display.
NOTE
If the run time is set to
OFF
, the comfort functions do not take effect.
General parameters
Run time and turn time