7.3 Temperature control
The temperature control of the Quatronic dialog is equipped with inside and
outside thermometers - also referred to as temperature sensors - and can
control your sun shading products according to the current temperature. This
lets you use your sun shading products to influence the temperature in your
rooms. The temperature control makes two operating modes available. One
mode lets you raise or lower the sun shading products on the basis of a
certain temperature. The second mode lets you use the temperature control
to switch on and off the sun control. This lets you independently control the
effects of the light and heat produced by the sun's radiation.
The two operating modes of the temperature control are:
The temperature control triggers an UP/DOWN move command.
The temperature control switches the sun control on or off.
7.3.1 Setting the temperature
control
The following parameters can be set for the temperature control:
Out
= Outside temperature below limit value triggers an "Up"
move command.
Out
= Outside temperature above limit value triggers a "Down"
move command.
In
= Inside temperature below limit value triggers an "Up" move
command.
In
= Inside temperature above limit value triggers a "Down"
move command.
InOM
= Inside temperature switches sun control on/off or triggers a
direct move command
OutOM
= Outside temperature switches sun control on/off or triggers
a direct move command
Alloc
= Inside temperature sensor allocation