WAREMA 6M REG Скачать руководство пользователя страница 5

5

warema_890012_alhb_en_v12•2022-05-01

We reserve the right to make technical modifications

WAREMA climatronic®

Schaltaktor 4M

     F1 6,3 

AT

 H

     F2 6,3 

AT

 H

WAREMA climatronic®

Schaltaktor 6M

     F1 6,3 

AT

 H

     F2 6,3 

AT

 H

     F3 6,3 

AT

 H

L

N

PE

1

3

2

BU BK BN

GNYE

M∼

Motor 1

Sun shading system

1

3

2

BU BK BN

GNYE

M∼

Motor 2

Sun shading system

N

PE

N

PE

1

3

2

BU BK BN

GNYE

M∼

Motor 3

Sun shading system

1

3

2

BU BK BN

GNYE

M∼

Motor 4

Window 230 V

N

PE

N

PE

Lighting

1

3

2

BU BK BN

GNYE

M∼

Motor 5

Sun shading system

N

PE

 H1

 H2

1

3

2

BU BK BN

GNYE

M∼

Motor 6

Sun shading system

1

3

2

BU BK BN

GNYE

M∼

Motor 7

Sun shading system

N

PE

N

PE

1

3

2

BU BK BN

GNYE

M∼

Motor 8

Sun shading system

1

3

2

BU BK BN

GNYE

M∼

Motor 9

Sun shading system

N

PE

N

PE

N

CLOSE

OPEN

Power line provided

by customer 

230 V AC, 50 Hz, 

16 A, 3 x 1.5 mm

2

ATTENTION:

 

Only one motor can be connected 

per motor terminal set. 

Parallel connection will 

damage the motor.

The total power (of all 4 outputs) 

per fuse must not exceed 1000 VA.

All motor lines 

H05-RR-F 4 G 0.75 black 

type WAREMA

All push button lines 

JY(St)Y 2x2x0.8 mm

Max. line length 200 m for 

interference-proof routing, 

use a twisted pair line.

All bus lines 

JY(St)Y 4×2×0.8 mm 

L

N

PE

L

N

PE

Example: Group push 

button, motor 7 and motor 8

Connection of group push 

buttons at the locking inputs. 

The locking function is no 

longer available. The relevant 

group is freely programmable 

within an actuator (see 

WAREMA climatronic

®

 

installation instructions)

Example: group 

push button, motor 

5 and motor 6

Groups are built for 

all actuators by 

"jumpering".

Only connect In+ for 

the actuators in the 

group.

Only connect P for 

the actuators in the 

group.

Example: 

Single push 

button, 

motor 1

S1

From 

previous 

bus device

Bus A

Bus B

0 V

24 V DC

To next 

bus device

Bus A

Bus B

0 V

24 V DC

Power supply 

unit

24 V DC

Zuleitung

bauseitig

230 V AC, 50 Hz

3 x 1,5 mm

2

Bus A

Bus B

0 V

Bus A

Bus B

0 V

Example: 

Group push 

button, motor 2 

and motor 3

Groups are built 

by means of 

"jumpering"

Example: Further power 

supply unit 24 V DC

If the power from one power 

supply unit is not sufficient, an 

additional power supply unit is 

needed. Subdivide the 24 V 

wire into subsections. Do not 

operate power supply units in 

parallel. The 0-V wire must 

always be connected through 

all components.

Example: Interlocking 

via window contact

Operation is enabled 

when the window is shut. 

This function must be 

programmed accordingly.

P

P

Fig. 5 

Connection example for switch actuators 4M and 6M