background image

15

P100-991-400B

P100 Warranty

Limited Warranty

Wanner Engineering, Inc. extends to the original purchaser 

of equipment manufactured by it and bearing its name, a 

limited one-year warranty from the date of purchase against 

defects  in  material  or  workmanship,  provided  that  the 

equipment is installed and operated in accordance with the 

recommendations and instructions of Wanner Engineering, 

Inc. Wanner Engineering, Inc. will repair or replace, at its 

option,  defective  parts  without  charge  if  such  parts  are 

returned with transportation charges prepaid to Wanner 

Engineering,  Inc.,  104  Chestnut  Avenue,  Minneapolis, 

Minnesota  55403.

This warranty does not cover:
1.  The  electric  motors  (if  any),  which  are  covered  by 

the  separate  warranties  of  the  manufacturers  of  these 

components.
. Normal wear and/or damage caused by or related to 

abrasion,  corrosion,  abuse,  negligence,  accident,  faulty 

installation or tampering in a manner which impairs normal 

operation.
3. Transportation costs.
This  limited  warranty  is  exclusive,  and  is  in  lieu  of  any 

other warranties (express or implied) including warranty 

of  merchantability  or  warranty  of  fitness  for  a  particular 

purpose  and  of  any  non-contractual  liabilities  including 

product  liabilities  based  on  negligence  or  strict  liability. 

Every  form  of  liability  for  direct,  special,  incidental  or 

consequential  damages  or  loss  is  expressly  excluded 

and denied.

Содержание P100

Страница 1: ...ervice P100 991 2400B P100 Metering Pump Metallic Pump shown 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www hydra cell com metering...

Страница 2: ...ry for performance characteristics of pumps with PTFE diaphragms Consult factory for performance specifications Gallons Per Hour GPH Maximum Flow at Designated Pressure GPH All Pumps GPH Metallic Pump...

Страница 3: ...0 1 50 1 60 1 80 1 100 1 W0036 1 2 NPT or 1 2 BSPT 3 8 NPT or 3 8 BSPT OUT IN 5 75 146 1 7 27 184 7 8 61 218 7 9 03 229 4 0 41 10 4 4X 5 65 143 5 4 50 114 3 0 78 19 8 5 90 149 9 6 50 165 1 NEMA 56C 0...

Страница 4: ...t the inlet line will not be obstructed See Inlet Piping on page 6 Positive Displacement This is a positive displacement pump To avoid severe system damage if the discharge line ever becomes blocked i...

Страница 5: ...more than one pump from the same inlet line Note System back pressure must exceed the pump inlet pressure by at least 15 psi 1 bar in order to prevent flow thru Discharge Piping Hose and Routing Use t...

Страница 6: ...tions are tight The oil reservoir beneath the reservoir diaphragm 71 is completely full NOTE The reservoir is filled and sealed at the factory If you are unsure about the oil level remove the cover 70...

Страница 7: ...lastic retainer is used Outlet Valve Insert dampening washer 10 valve seat 9 Tetra seal 7 valve 6 spring 5 and spring retainer 4 Install flat Tetra seal O ring 14 between spring retainer 4 and valve s...

Страница 8: ...Watch oil level in reservoir If oil gets too low during priming air will be drawn into piston inside hydraulic end Air will cause pump to have loss in flow and repriming will be necessary Fill oil re...

Страница 9: ...P100 991 2400B W0039 R O P100 Fluid End Parts List Bolt Torque Specifications Ref No in lbs N cm 1 90 1 017 20 14 158 22 10 113 23 14 158 W0037 W0040 W0038...

Страница 10: ...ST 1 D10 020 1017 Valve Seat inlet Hastelloy C 1 D10 020 3300 Valve Seat inlet ceramic 1 14 D10 092 2110 Tetra Seal inlet Buna 1 D10 092 2111 Tetra Seal inlet Viton 1 D10 092 2112 Tetra Seal inlet neo...

Страница 11: ...1033 Pump Housing 1 65 D10 085 2210 Key shaft 1 69 D10 038 2210 Plug drain 1 70 F20 105 1020 Cover Nameplate oil reservoir SST 1 71 F20 091 1010 Diaphragm oil reservoir 1 72 G20 090 2010 Screw cap hex...

Страница 12: ...1 112 109 Reducer 60 1 ratio 56C 1 112 110 Reducer 80 1 ratio 56C 1 112 111 Reducer 100 1 ratio 56C 1 101 112 112 Kit Protective Cover 1 102 112 116 Kit Output Flange FD 1 103 108 108 101 100 105 103...

Страница 13: ...ief valve or repair clean or replace with new relief valve Delivery Too Low and or Erratic Review all Probable Causes and Solutions in Problem 2 No Delivery above Air leak s in inlet line Locate all l...

Страница 14: ...Diaphragm Kit 6 9 5 3 2 1 8 4 Kit Designator Part Number Description Qty K D V D03 018 ___ Diaphragm 1 F20 073 ___ O ring outlet manifold 1 F20 074 ___ O ring inlet manifold 1 D03 035 ___ O ring outle...

Страница 15: ...t Avenue Minneapolis Minnesota 55403 This warranty does not cover 1 The electric motors if any which are covered by the separate warranties of the manufacturers of these components 2 Normal wear and o...

Страница 16: ...Revised 2 2007 2005 Wanner Engineering Inc Printed in USA 1204 Chestnut Avenue Minneapolis MN 55403 TEL 612 332 5681 FAX 612 332 6937 TOLL FREE FAX US only 800 332 6812 www hydra cell com metering em...

Отзывы: