BATT STATUS: UNKNOWN OR GOOD
<FUNCTION> TO CHANGE
**
(**) APPEARS ONLY WHEN A (GOOD) BATTERY IS BEING LEARNED!
A battery “Adapter Cup” holds a total of 5 battery profiles for parameter storage; four are preprogrammed
SELECTED CAPACITY =
1800 MAHR
ENTER THE NEW CHARGE
RATE: 1000 MA
ENTER NEW DIS -CHRG
RATE: C/2
NOMINAL IMPEDANCE =
250 mOHMS
LION 1CELL 1800MAH
CHRG: 1000MA C /:2
LEARN MODE COMPLETE
Mode”. During entry into the “Learn Mode”, Battery Chemistry, Capacity, and the number of Cells are
BATTERY TYPE =
LITHIUM ION
PASS / FAIL LEVEL =
80% OF CAPACITY
ACCEPT DEVIATION =
35%
STORING NEW
CONFIGURATION
INSERT BATTERY
REMOVE BATTERY
CELL COUNT =
2 CELLS
LEARN MODE
SELECTED
SELECTING “ LEARN “
AND RESULTS
This mode when selected will allow a battery’s parameters to be created for new battery models.
with OEM information for a particular battery series. The fifth profile can be modified by the “Learn
EMPTY
EMPTY
READY
prompted for data entry. Follow the Directions below to enter data for the Learn Mode.
REMOVE BATTERY
Display After “Turn On”
NO ACTION
NO ACTION
NO ACTION
ACTION
NO ACTION
PUSH BUTTON ONCE
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
Chemistry (Lithium Ion, Nickel Cadmium, and Nickel Metal Hydride)
PUSH
Important:
It is important that when testing
an
in the
that
you select the
state as opposed to
the
state until the battery has been
certified to be equal to or greater than 95% of
it’s rated capacity, then perform an Impedance
test and record the results, repeat the learn
mode with:
as
Once a
good battery is learned, you will be able to
perform a QUICK TEST in station (1) of the X3
and on stations (1) and (4) of the X6.
UNKNOWN BATTERY
learn mode
UNKNOWN
GOOD
BATT STATUS:
GOOD.
.
16
Learn Mode Precautions
A good battery must be used to calibrate a
battery’s profile. OEM batteries have unique
profiles that should not be used when testing
non-OEM batteries. For each new non-OEM
battery, create a new profile. The factory
settings can not be modified in the field,
however by utilizing the
function one can learn a non-OEM battery.
It is very important that the battery you are
using the LEARN MODE function for must be
at least 95% of the stated capacity and a
should be performed on
the battery in question and entered when
requested in the LEARN MODE. It is a good
idea to set the acceptable deviation to
35% to begin with. The learning of a good
non-OEM battery will enable you to perform
a QUICK TEST (QT) in station #1 of the X3 and
stations #(1) and #(4) of the X6.
LEARN MODE
Impedance test
# Of Cells
1-12 NiCd and 1-4 Li-ion
Capacity 100 - 4000 maH
Learn Mode
Data Range
*
Impedance Test
Impedance of a battery can be a good indicator of degradation of a battery’s performance. In general, the lower
the impedance number the better the battery performance during discharge. As a battery ages the
impedance starts to rise indicating possible problems with the electrolyte, separator, contact corrosion, or
metal interfaces, all impact the impedance.
The initial impedance of a new battery should be recorded and compared through the life of a battery and a
determination can be made to remove the battery from service when the impedance rises out of range.
The Analyzer X3 and X6 produce impedance results within a 15 seconds of testing and displays the impedance in
Ohms on the display or on a printout when an optional printer is used.
Follow the directions
This test is only performed in Pocket #1 for the X3 and pockets #1 and #4 for the X6.
below for Impedance
FOR RESULTS
Display After “Turn On”
After the battery is placed
in the adapter
PUSH FUNCTION BUTTON
until battery
specs appear
in the display
SELECTING “IMPEDANCE “
AND RESULTS
testing.
NO ACTION
NO ACTION
NO ACTION
NO ACTION
PUSH
PUSH
PUSH
PUSH
PUSH
ACTION
PUSH
15
CYCLE/AUTO/CONDITION
<FUNCTION> FOR NEXT
DIS -CHRG BATTERY
<FUNCTION> FOR NEXT
BATTERY IMPEDANCE
.233 ohms
<FUNCTION> FOR NEXT
NICD 700 MAH 7.2V
<FUNCTION> FOR NEXT
QUICK TEST
<FUNCTION> FOR NEXT
<FUNCTION> FOR NEXT
NICD 700 MAH 7.2V
HAS BEEN SELECTED
HAS BEEN SELECTED
TO PROCEED PRESS
<FUNCTION>
CHARGE BATTERY
IMPEDANCE TEST
IMPEDANCE TEST
EMPTY
TESTING
READY