background image

*

**

BATT STATUS: UNKNOWN OR GOOD

<FUNCTION> TO CHANGE

**

(**) APPEARS ONLY WHEN A (GOOD) BATTERY IS BEING LEARNED!

A battery “Adapter Cup” holds a total of 5 battery profiles for parameter storage; four are preprogrammed

SELECTED CAPACITY =

1800 MAHR

ENTER THE NEW CHARGE

RATE: 1000 MA

ENTER NEW DIS -CHRG

RATE: C/2

NOMINAL IMPEDANCE =

250 mOHMS

LION 1CELL 1800MAH

CHRG: 1000MA C /:2

LEARN MODE COMPLETE

Mode”. During entry into the “Learn Mode”, Battery Chemistry, Capacity, and the number of Cells are

BATTERY TYPE =

LITHIUM ION

PASS / FAIL LEVEL =

80% OF CAPACITY

ACCEPT DEVIATION =

35%

STORING NEW

CONFIGURATION

INSERT BATTERY

REMOVE BATTERY

CELL COUNT =

2 CELLS

LEARN MODE

SELECTED

SELECTING “ LEARN “

AND RESULTS

This mode when selected will allow a battery’s parameters to be created for new battery models.

with OEM information for a particular battery series. The fifth profile can be modified by the “Learn

EMPTY

EMPTY

READY

prompted for data entry. Follow the Directions below to enter data for the Learn Mode.

REMOVE BATTERY

Display After “Turn On”

NO ACTION

NO ACTION

NO ACTION

ACTION

NO ACTION

PUSH BUTTON ONCE

PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

PUSH

Chemistry (Lithium Ion, Nickel Cadmium, and Nickel Metal Hydride)

PUSH

Important:

It is important that when testing

an

in the

that

you select the

state as opposed to

the

state until the battery has been

certified to be equal to or greater than 95% of
it’s rated capacity, then perform an Impedance

test and record the results, repeat the learn

mode with:

as

Once a

good battery is learned, you will be able to
perform a QUICK TEST in station (1) of the X3
and on stations (1) and (4) of the X6.

UNKNOWN BATTERY

learn mode

UNKNOWN

GOOD

BATT STATUS:

GOOD.

.

16

Learn Mode Precautions
A good battery must be used to calibrate a
battery’s profile. OEM batteries have unique
profiles that should not be used when testing
non-OEM batteries. For each new non-OEM
battery, create a new profile. The factory
settings can not be modified in the field,
however by utilizing the
function one can learn a non-OEM battery.
It is very important that the battery you are
using the LEARN MODE function for must be
at least 95% of the stated capacity and a

should be performed on

the battery in question and entered when
requested in the LEARN MODE. It is a good
idea to set the acceptable deviation to
35% to begin with. The learning of a good
non-OEM battery will enable you to perform
a QUICK TEST (QT) in station #1 of the X3 and
stations #(1) and #(4) of the X6.

LEARN MODE

Impedance test

# Of Cells

1-12 NiCd and 1-4 Li-ion

Capacity 100 - 4000 maH

Learn Mode

Data Range

*

Impedance Test

Impedance of a battery can be a good indicator of degradation of a battery’s performance. In general, the lower
the impedance number the better the battery performance during discharge. As a battery ages the
impedance starts to rise indicating possible problems with the electrolyte, separator, contact corrosion, or
metal interfaces, all impact the impedance.
The initial impedance of a new battery should be recorded and compared through the life of a battery and a
determination can be made to remove the battery from service when the impedance rises out of range.

The Analyzer X3 and X6 produce impedance results within a 15 seconds of testing and displays the impedance in
Ohms on the display or on a printout when an optional printer is used.

Follow the directions

This test is only performed in Pocket #1 for the X3 and pockets #1 and #4 for the X6.

below for Impedance

FOR RESULTS

Display After “Turn On”

After the battery is placed
in the adapter

PUSH FUNCTION BUTTON
until battery
specs appear
in the display

SELECTING “IMPEDANCE “

AND RESULTS

testing.

NO ACTION

NO ACTION

NO ACTION

NO ACTION

PUSH

PUSH

PUSH

PUSH

PUSH

ACTION

PUSH

15

CYCLE/AUTO/CONDITION

<FUNCTION> FOR NEXT

DIS -CHRG BATTERY

<FUNCTION> FOR NEXT

BATTERY IMPEDANCE

.233 ohms

<FUNCTION> FOR NEXT

NICD 700 MAH 7.2V

<FUNCTION> FOR NEXT

QUICK TEST

<FUNCTION> FOR NEXT

<FUNCTION> FOR NEXT

NICD 700 MAH 7.2V

HAS BEEN SELECTED

HAS BEEN SELECTED

TO PROCEED PRESS

<FUNCTION>

CHARGE BATTERY

IMPEDANCE TEST

IMPEDANCE TEST

EMPTY

TESTING

READY

Содержание X3

Страница 1: ...res 4 Specifications 5 Part Overview 6 Understanding the X3 s adapters Cup 7 Getting started 8 Quick Test Analysis 9 Cycle Mode 10 Auto Mode 11 Condition Mode 12 Discharge Mode 13 Learn Mode 16 Safety...

Страница 2: ...rges Nickel Cadmium and Nickel Metal Hydride batteries Analyzes and charge lithium Ion and lithium polymer batteries Features a single button capable of multifunction and an easy to read display for a...

Страница 3: ...rrent with negative delta V Detection 20x2 2 Backlit LCD Quick Connect Adapter Cups for ease of changing Adapters No tools required Five Memory locations each can be programmed for Li ion NiCD or NiMH...

Страница 4: ...e and discharge rate for 4 battery types There is a fifth data position in the cup reserved for user defined information during the Learn Mode See for more information Learn Mode 1 Place a battery int...

Страница 5: ...EED PRESS FUNCTION LION 1650 MAH 7 4V FUNCTION FOR NEXT LION 1650 MAH 7 4V HAS BEEN SELECTED HAS BEEN SELECTED QUICK TEST QUICK TEST TEST FUNCTION FOR NEXT ACTION DISPLAY QUICK TEST ANALYSIS 9 Cycle M...

Страница 6: ...NCTION FOR NEXT Auto Mode 11 SELECTING AUTO RESULTS SELECTING CONDITION AND RESULTS Condition Mode The CONDITION CYCLE serves basically two needs of Nickel based batteries one is to reform the Cells o...

Страница 7: ...ollow the directions below Charge Mode ACTION Display After Turn On After the battery is placed in the adapter NO ACTION NO ACTION NO ACTION NO ACTION NO ACTION FOR RESULTS PUSH FUNCTION BUTTON until...

Страница 8: ...modified in the field however by utilizing the function one can learn a non OEM battery It is very important that the battery you are using the LEARN MODE function for must be at least 95 of the state...

Страница 9: ...ifferent parameters for the same battery just repeat the Learn mod process again UNKNOWN BATTERY learn mode UNKNOWN GOOD One must observe the proper polarity when connecting the battery to the Univers...

Отзывы: