Cleaning / changing the chuck

 

Clean the inside and outside of the shaft using the cleaning brush .

  Apply 2 drops of oil into the hole in the shaft and outside of the chuck .

 

Insert the chuck .

 

Insert the chuck key up to the limit stop in the chuck and screw clockwise .

Hold the shaft firmly with the spanner .

Содержание Perfecta 900

Страница 1: ...Instructions for use Translation of the original operating manual 900...

Страница 2: ...operation Motor handpiece Blow out function 23 10 Description of the operating controls Assemble support optional 24 25 11 Operating the operating controls Reverse operation Changing the speed Changi...

Страница 3: ...isk to persons or objects W H Service Only for USA Caution Federal law restricts this device to sale by or on the order of a dentist physician or any other practitioner licensed by the law of the stat...

Страница 4: ...ent AC VA Electric power input of the unit Electric fuse Supply voltage of the unit V Supply current A Frequency of the alternating current Hz Data Matrix Code only for certain models for product iden...

Страница 5: ...or any other practitioner licensed by the law of the state in which he or she practices to use or order the use of the device Fragile handle with care Keep away from rain Temperature limit Humidity l...

Страница 6: ...a dental laboratory whereby the handpiece is guided by hand The control unit is not designed as a piece of medical equipment It is not permitted for use on patients Skilled application The Perfecta i...

Страница 7: ...nufacturer W H Dentalwerk B rmoos can only accept responsibility for the safety reliability and performance of the Perfecta when there is compliance with the following directions Consult Instructions...

Страница 8: ...and can be disposed of through branch recycling companies However werecommendthatyoukeeptheoriginalpackaging Lift out the accessories carton Knee control unit Remove the holding plate and fitting for...

Страница 9: ...starter L NV REF 05038100 m Foot stand for control unit REF 04820800 Knee Table control unit m Motor cable 1 8 m for LA 9 REF 05117800 m Hose for air supply REF 05250400 m Motor handpiece LA 9 withou...

Страница 10: ...d starter L NV REF 05038100 Knee Table control unit m Motor cable 1 8 m for LA 9 REF 05117800 m Hose for air supply REF 05250400 m Hose for coolant supply REF 05075600 m Motor handpiece LA 9 without m...

Страница 11: ...rve the contents of the safety data sheet for the material you are working with The Perfecta is intended for use at a dental technician s workstation suction protective equipment Use only suitable and...

Страница 12: ...heres Power failure In the event of a power failure or if the Perfecta is switched off the last speed set is saved and re activated on power up Intermittent operating mode S6 4min 10min is the designa...

Страница 13: ...nnecting socket for operating controls Power socket Coolant regulator Power switch ON OFF I 0 Connecting socket for motor handpiece LA 9 LA 66 optional Air supply Coolant supply control unit with exte...

Страница 14: ...g template or holding plate Pre drill 4 screw holes with 3 mm Note dimensions H 550 to 600 mm H1 at least 90 mm D 90 mm control unit with external coolant supplying 125 mm control unit with internal c...

Страница 15: ...itioning Insert control unit up to the limit stop on the holding plate One drop of oil makes insertion easier Push in the fitting for the blow out function up to the limit stop Switch on control unit...

Страница 16: ...ower socket Power switch ON OFF I 0 Fuse holder with 2 fuses Foot stand Production year Connecting socket for foot operated starter optional Connecting socket for operating controls Connecting socket...

Страница 17: ...wer socket Power switch ON OFF I 0 Fuse holder with 2 fuses Connecting socket for foot operated starter Connecting socket for operating controls Production year Air supply Coolant supply Connecting so...

Страница 18: ...ith external coolant supplying and mains cable Note the positioning Assemble the control unit onto the foot stand with compressed operating panel control unit with internal coolant supplying Note the...

Страница 19: ...lant tank Pressure build up in the coolant tank Push in the coolant tank until it engages audibly Only insert a deaerated coolant tank By ventilation at the first filling or if the coolant tank was em...

Страница 20: ...20 General starting operation Regulating coolant Increase coolant Decrease coolant...

Страница 21: ...ling device adaptor optional for the motor handpiece can be fastened above or below the expansion ring The milling device adaptor optional has a diameter of 16 or 18 mm on either side for use with dif...

Страница 22: ...22 Description of the motor handpiece LA 66 optional Front sheath Motor handpieceLA 66 optional Rear sheath Cap Tip Motor cable...

Страница 23: ...operation start motor handpiece blow out function Start motor handpiece by pressing the knee control unit or the foot operated starter Activate the blow out function by constantly pressing the button...

Страница 24: ...lay Forward reverse operation mode Bistable operation Changing motor handpiece Coolant spray Program button Forward reverse operation mode Program button Changing motor handpiece coolant supplying Pro...

Страница 25: ...tion of the operating controls Assemble support optional The support optional can be moved into a variety of assembly positions by simultaneously pressing both buttons on the joint Assemble the suppor...

Страница 26: ...erating controls Reverse operation mode You can switch between forward and reverse operation by pressing the program button When switching to reverse operation an audible signal sounds and the LED ill...

Страница 27: ...LA 66 optional 1 000 40 000 rpm are continuously increased decreased Increase speed Decrease speed Press the control knob Keep the control knob pressed down and turn it Set the speeds from 80 000 100...

Страница 28: ...n audible signal sounds No LED illuminates Start motor handpiece by pressing the pedal or flap At the change on motor handpiece LA 9 the coolant spray becomes co activated automatically Deactivating r...

Страница 29: ...cted maximum speed is automatically reached during motor start he motor handpiece runs independently Deactivation of bistable operation Press program button x 2 Start or stop the motor handpiece by ta...

Страница 30: ...e motor handpiece runs independently Deactivation of speed control operation Press the program button x 1 Stop the motor handpiece by tapping the pedal or flap Start the motor handpiece until the requ...

Страница 31: ...1 12 Removing and assembling the motor handpiece Unscrew the cap LA 9 Assemble and tighten the cap Note the positioning Unscrew the cap LA 66 optional Assemble and tighten the cap Note the positioning...

Страница 32: ...rotary tool up to the limit stop or remove Turn the expansion ring anti clockwise until it engages audibly LA 9 Turn the front sheath clockwise up to the limit stop Push in the rotary tool up to the l...

Страница 33: ...the event that the motor handpiece starts accidentally the electronic system switches off Test run Start the motor handpiece In the event of malfunctions e g vibrations unusual noises overheating sto...

Страница 34: ...34 14 Cleaning The cleaning of the Perfecta control unit motor handpiece operating controls optional foot operated starter optional can take place by means of a dry cloth...

Страница 35: ...ush are located on the underside of the handpiece holder Insert the chuck key up to the limit stop in the chuck and unscrew anticlockwise Hold the shaft firmly with the spanner Remove the chuck Turn t...

Страница 36: ...outside of the shaft using the cleaning brush Apply 2 drops of oil into the hole in the shaft and outside of the chuck Insert the chuck Insert the chuck key up to the limit stop in the chuck and scre...

Страница 37: ...ics overheating safety shutdown Switch off the equipment cool for at least 10 minutes and then re start E01 Motor handpiece overloading Drive blocked Connect motor handpiece or close the chuck mechani...

Страница 38: ...ot operated starter L NV 05075600 Hose for coolant supply 05138000 Support for operating controls optional 05243400 Operating controls LA 9D 05250400 Hose for air supply 06319400 Adaptor for milling d...

Страница 39: ...H service partner see Page 45 Always return equipment in the original packaging Do not coil the cable around the motor handpiece and do not twist or kink the motor cable Risk of damage Regular checkin...

Страница 40: ...tent loading Noise 55 dBA Vibration 2 5 m s Height width depth and weight with internal coolant supplying Knee control unit without lever 306 128 317 mm with lever 306 187 340 mm and 6 0 kg Table cont...

Страница 41: ...to 80 relative non condensing Temperature in operation 5 C to 40 C Air humidity in operation maximum 80 relative with a temperature of up to 31 C decreasing arithmetically up to a maximum of 50 relati...

Страница 42: ...ated starter motor handpiece Follow your country specific laws directives standards and guidelines for the disposal of used electrical devices Disposal of the packaging material All packaging material...

Страница 43: ...or material or manufacturing defects within a warranty period of 24 months from the date of purchase We accept no responsibility for damage caused by incorrect handling or by repairs carried out by th...

Страница 44: ...44 CE Declaration of conformity...

Страница 45: ...nited Kingdom t 44 1727 874990 f 44 1727 872254 E Mail technical uk wh com W H Impex Inc 6490 Hawthorne Drive Windsor Ontario N8T 1J9 Canada t 1 800 2656277 1 519 9446739 f 1 519 9746121 E Mail servic...

Страница 46: ...Manufacturer W H Dentalwerk B rmoos GmbH Ignaz Glaser Stra e 53 5111 B rmoos Austria t 43 6274 6236 0 f 43 6274 6236 55 office wh com wh com Form Nr 50596 AEN Rev 011 19 04 2016 Subject to alterations...

Отзывы: