background image

Note

:

if the Osmo demineralizer is used to supply sterilizers with demineralized water, it is imperative to monitor the water quality. If the supplied

sterilizers do not feature a water conductivity sensor to monitor the water quality, we recommend using the manual water conductivity
meter

Primo 5.

Electrical connection

Before plugging in the unit to the power socket, check that the voltage shown on the rating plate, corresponds to the one of your work
place.

Earthing of the equipment is compulsory by law. Any deliberate cutting of the earth wire inside or outside the unit or removal of
the earth terminal from the plug is forbidden in that the unit becomes hazardous.

The manufacturer declines all responsibility in respect to persons or things arising from failure to observe this rule. The electrical safety of
this unit is only guaranteed when it is correctly connected to an effective earthing system, as provided by current electrical safety laws.
If you do not have an electrical system with proper earthing, do not connect the unit to the socket and consult a specialist electrician as
soon as possible.

General information and Safety advice

6

This equipment requires earthing.

BEFORE STARTING UP THE EQUIPMENT

Check that the equipment has not been damaged

. Do not use products which have been damaged during transport; if in

doubt consult the retailer or the manufacturer directly.

Use of the Osmo, as with any other equipment connected to an electrical system, involves compliance with certain fundamental safety rules:

do not touch the reverse osmosis purifying system with wet or damp hands or feet;

do not (dis)connect the plug to/from the socket with wet hands;

do not pull the power cord to disconnect the plug from the power outlet;

do not leave the reverse osmosis purifying system exposed to atmospheric agents;

do not allow the reverse osmosis purifying system to be used by children without supervision;

before carrying out any cleaning or maintenance operation, disconnect the reverse osmosis purifying system from the electricity mains
by taking out the plug from the power socket;

in the event of a fault or poor operation, switch off the Osmo and do not tamper with it. Contact an authorized technician for any intervention;
if parts of the reverse osmosis purifying system are replaced, for maintenance or due to a fault, by an unauthorized technician, make sure
the parts comply with the legislation in force.

Содержание Osmo

Страница 1: ...Osmo ENG Rev 00 Instructions for use...

Страница 2: ...Contents of the packaging 9 4 Conditions of use and period of use 11 5 Installation 12 6 Priming 20 7 Use and operation 21 8 Maintenance 22 9 Water Block safety valve 27 10 Spare parts 29 11 Troubles...

Страница 3: ...ent of risk of damage to property W H symbols Consult the instructions for use High voltage Do not open or tamper with the equipment Live electric parts inside the unit Do not dispose of with normal w...

Страница 4: ...ranty covers replacement or repair of the components recognized as being unsuitable due to manufacturing defects inclusive of the necessary labor The above is not applicable to faults caused by incorr...

Страница 5: ...al absence of chemical products The Osmo can eliminate from water all impurities and harmful pollutants Treated water is the ideal solution for professional use and delivery since the exclusive filtra...

Страница 6: ...General information and Safety advice 6 This equipment requires earthing BEFORE STARTING UP THE EQUIPMENT Check that the equipment has not been damaged Do not use products which have been damaged dur...

Страница 7: ...ing to the instructions in this manual or is not properly maintained the manufacturer cannot be held responsible for any fault damage or malfunctioning of the equipment If the tap water shows high qua...

Страница 8: ...ther The permitted temperature is 5 C 35 C Even if carefully packaged and protected the system must be considered and handled as fragile material On receipt check the external conditions of the packag...

Страница 9: ...Open the package and check that the contents correspond to the delivery note and to the list in the next page there is no evidence of any damage In the event of damage or missing items inform the car...

Страница 10: ...nal connecting tubes support bracket kit optional 2 7 litre storage tank with a tap 3 Water Block valve with filter and setting key 4 Opening closing tool for osmotic vessel cap 5 Dowels and screws fo...

Страница 11: ...lacement and flush filter cartridge for 5 minutes See label on the equipment and instructions for use Resin filter cartridge life Max 6 months or exhaustion Replacement See instructions for use Osmoti...

Страница 12: ...m WB Valve The safety valve Water Block prevents a water flow greater than the set value which is the flow requested by the appliance connected This prevents big leaks in case a vessel or a tube gets...

Страница 13: ...unted installation Install the osmotic group using the 4 supplied dowels and screws OR Installation with brackets optional Install the brackets on the osmotic group using the 4 screws and nuts Install...

Страница 14: ...8 mm to the Water Block valve outlet Attention seal the thread with PTFE tape Do not use glue nor paste as a sealant 4 Remove the red cap from the IN fitting of the Osmo and tighten the quick connecto...

Страница 15: ...e the tube out of the fitting press the fitting ring with your fingers and pull out the tube Note To allow the complete installation of the Osmo the white tube needs to be cut into several pieces 6 Co...

Страница 16: ...om the fitting TANK of the Osmo in the storage tank tap and tighten it with the ring nut 9 Connect the white tube in the fitting OUT of the Osmo This is a quick connector fitting insert the tube until...

Страница 17: ...he water dispenser in the other free fitting of the T connection Note tighten the tubes connected to the T connection with the ring nuts 12 Connect the white tube in the fitting DRAIN of the Osmo This...

Страница 18: ...Installation 18 Example of installation Connection to Water dispenser Tap optional...

Страница 19: ...Installation 19 EXAMPLES OF USAGE Description Image Manual use with water dispenser for manual filling of the sterilizer tank and washing of instruments Manual usage with tap optional...

Страница 20: ...ge and there are no traces of water on the bottom of the equipment Do not operate the equipment without having opened the water supply first The pump can suffer irreparable damage if run dry 2 Let the...

Страница 21: ...O AVOID WATER CONTAMINATION 7 Use and operation 21 In accordance with subsection 4 5 of EN1717 in order to avoid water quality degradation and bacterial growth the entire system must be drained before...

Страница 22: ...year in case a sterilizer is attached to the system this could be done during the scheduled maintenance visits for the sterilizer It is further recommended to check all related devices fitted to the s...

Страница 23: ...over 15 S after the filter cartridge maintenance kit has been replaced also replace the osmotic membrane All the filter cartridges can vary slightly which in combination with unfavourable operational...

Страница 24: ...hausted filter cartridge counter clockwise and remove it Note during this operation water will inevitably pour out of the vessel 5 Insert the new filter cartridge and turn it clockwise to the end unti...

Страница 25: ...e electrical power supply 2 Close the water inlet tap and the storage tank tap 3 If present release the water pressure with the use of the water dispenser or tap if connected optional 4 Using the appr...

Страница 26: ...he new membrane completely making sure that the two o rings are positioned correctly Tighten the osmotic vessel cap by turning it clockwise with the appropriate tool Note check carefully that there ar...

Страница 27: ...0 N cm2 Max controllable volume about 50 lt Min operating capacity 2 lt min Max operating capacity 30 lt min Max water temperature 70 C USER INSTRUCTIONS Water Block should be installed between the ta...

Страница 28: ...f and carry out the necessary repair work Remove the supply hose C from the Water Block and press the coloured plunger H which is located inside the lower housing of the device itself fig 1 It may be...

Страница 29: ...lter cartridges A813030X Complete maintenance kit resin carbon filter cartridges osmotic membrane A813053X No 2 quick connector fittings tube 8 mm A813031X Pump 230 V A813032X Pump 115 V A813033X Sole...

Страница 30: ...Resin filter cartridge head A813043X Carbon filter cartridge head A813042X Osmotic vessel A813046X L shaped quick fitting 8 mm for black tube A813047X L shaped quick fitting 6 mm for white tube A8130...

Страница 31: ...ption Code Drawing Image Pressure switch A813052X Water dispenser kit A812018X Water tap kit optional A813044X Support bracket kit optional A813045X Pressure reducer x 3 bar optional A813025X Spare pa...

Страница 32: ...ower supply water inlet presence Water inlet problem Water Block operated Set the Water Block properly The motor pump starts by itself at regular intervals Leak on the supply circuit downstream of the...

Страница 33: ...ed power 230 V 138 W Max absorbed power 115 V 138 W Class of insulation III Min max supply pressure 0 5 5 bar Usage environment Indoor Weight with filter cartridges empty storage tank 13 kg Weight of...

Страница 34: ...ized and managed by the supplier The user shall contact the supplier and follow the method that has been implemented for disposing of the equipment at the end of its life The correct disposal techniqu...

Страница 35: ...Notes...

Страница 36: ...Osmo ENG Instructions for Use Rev 00 Subject to alterations 08 01 2021 W H Sterilization S r l Italy I 24060 Brusaporto BG via Bolgara 2 t 39 035 66 63 000 f 39 035 50 96 988 wh com...

Отзывы: