10. Fault Finding 

Make sure to disconnect the power before attempting to diagnose any fault.

Fault

Cause

Remedy

1. Motor does not run 

start.

Supply failure. 

Connect the electricity supply.

Fuses are blown.

Replace fuses.

Motor starter overload has 

tripped out.

Reactivate the motor protection.

Thermal protection has tripped 

out.

Reactivate the thermal protection.

Main contacts in motor starter 

are not making contact or the 

coil is faulty.

Replace contacts or magnetic coil.

Control circuit is defective.

Repair the control circuit.

Motor is defective.

Replace the motor.

2. Motor starter 

overload trips out 

immedia tely when 

supply is switched on.

One fuse / automatic circuit 

breaker is blown. 

Cut in the fuse.

Contacts in motor starter 

overload are faulty. 

Replace motor starter contacts.

Cable connection is loose  or 

faulty. 

Fasten or replace the cable 

connection.

Motor winding is defective. 

Replace the motor.

Pump mechanically blocked. 

Remove the mechanical blocking 

of the pump.

Overload setting is too low.

Set the motor starter correctly.

One fuse / automatic circuit 

breaker is blown. 

Cut in the fuse.

3. Motor starter 

overload trips out 

occasionally.

Overload setting is too low.

Set the motor starter correctly.

Low voltage at peak times.

Check the electricity supply.

4. Motor starter has not 

tripped out but the 

pump 

does not run.

Supply failure.

Connect the electricity supply.

Fuses are blown.

Replace fuses.

Thermal protection has 

tripped out.

Reactivate the thermal protection.

Main contacts in motor starter 

are not making contact or the 

coil is faulty.

Replace contacts or magnetic coil.

5. Pump runs but gives 

no liquid or pump 

capacity is not constant.

Liquid level in tank too low.

Increase the liquid level.

Pump draws in air.

Check the suction conditions.

6. Leakage in shaft seal. Shaft seal is defective.

Replace the shaft seal.

7. Noise.

Cavitation occurs in the pump.

Check the suction conditions.

Pump does not rotate freely 

(frictional resistance) because of 

incorrect pump shaft position.

Adjust the pump shaft.