S-Cape
™
2MR Hand Control Operation Guide 99300906
The six step procedure below is required to seperate 2 hand controls from operating 2 beds. One
hand contol per bed operation will result. Before beginning, make certain the beds are plugged into a
working grounded electrical outlet.
If programming fails, initiate the programming procedure a
second time.
NOTE: OPERATE ONLY ONE (1) HAND CONTROL AT A TIME. OPERATING TWO (2) HAND
CONTROLS AT THE SAME TIME WILL MOMENTARILY BLOCK BOTH RF SIGNALS AND PREVENT BOTH
CONTROLS FROM FUNCTIONING.
S-CAPE
™
2MR REPROGRAMMING
separating 2 beds
S T E P 4
The bed will be equipped with either a
power down box
or
J box
(
FIGURE 2
). Locate
the receiver unit for bed 2 and press the
learn
button
for 1 second and release.
S T E P 5
On hand control 2, simultaneously press and
hold the
POS 1
and the
head massage on/off
buttons
(
FIGURE 3
).
The transmission indicator
light will
flash slowly
and then
flash rapidly
to
indicate programming mode.
Continue to hold
for 5 seconds and then release the buttons.
S T E P 6
Repeat Step 4 and Step 5 with hand control 2.
Independent hand control operation is now
restored (hand control 1 operating bed 1; hand
control 2 operating bed 2).
S T E P 2
On hand control 1, simultaneously press and
hold the
POS 1
and the
head massage on/off
buttons
(
FIGURE 3
).
The transmission indicator
light will
flash slowly
and then
flash rapidly
to
indicate programming mode.
Continue to hold
for 5 seconds and then release the buttons.
S T E P 3
Repeat Step 1 and Step 2 with hand control 1.
Note: wait 90 seconds before proceeding to
Step 4.
STEP 1
The bed will be equipped with either a
power
down box
or
J box
receiver unit (
FIGURE 2
).
Locate the receiver unit for bed 1 and press the
learn button
for 1 second and release.
Note: If
you experience difficulty locating or reaching
the learn button on a J box equipped
adjustable bed, refer to
J Box Programming
on
page 5.
POS 1
BUTTON
TRANSMISSION
INDICATOR LIGHT
FIGURE 3
HEAD MASSAGE
ON/OFF BUTTON
HAND CONTROL 1
BED 1
BED 2
HAND CONTROL 2
J BOX
FIGURE 2: Power down box and J box receiver units.
LEARN
BUTTON
LEARN
BUTTON
POWER
DOWN BOX
POWER DOWN
BOX RECEIVER
UNIT IS NOT
MOUNTED TO
BED FRAME.
J BOX RECEIVER
UNIT IS MOUNTED
TO THE BOTTOM
SIDE OF THE
BED FRAME.