Revision 1
14
Product Manual PSH-30 series Hand Wash Dryer
1) Remove the basin fascia, with attached waste pipe, M10 studs, installation
brackets and air ducting relevant to the variant being installed from the
packaging.
To fit the four threaded studs into the mounting points on the rear side of the hand
basin, apply ‘Loctite 270’ onto the first 15mm of thread on each stud end to fit into the
sink corner fixing points. Screw each one in by hand until it stops & then un-screw
the stud by two full turns, Note the recommended cure time of 6 hours at room temp.
of 22°C or up to 24 hours at room temp. of 5°C for the Loctite to set.
NOTE: It is very important to install the studs correctly to prevent the
stud damaging the fascia.
Models without cold water outlet.
At the front top LH basin fascia position is
fitted 1 stainless steel operating button and bezel, marked ‘HANDWASH’ or
‘HANDWASH & DRIER’, (depending on model) at front RH position a blank
bezel plate to be fitted with either a plain plate or a plate with
legend ‘NOT
DRINKING WATER’.
Cold water outlet models.
At the front top LH basin fascia position is fitted 2
stainless steel operating buttons and bezels, front LH marked ‘HANDWASH’
or ‘HANDWASH & DRIER’, (depending on model) front RH with a plain bezel.
2)
Fit the solid surface basin fascia, with studs in place, fully into the aperture,
the flat underside of basin area sitting on the bottom of the aperture. Secure
the unit to the wall by placing the vertical retaining brackets onto the studs & fit
M10 fixings
NOTE: It is important to tighten the fixings adequately but avoid distorting
the metal brackets through excessive tightening. Tighten the M10 nuts to a
torque of 17Nm in a circular sequence. Do not overtighten as this may
cause damage to the fascia & retaining brackets.
Figure 3: PSH-30 fascia dimensions
Figure 4: Fascia clamping brackets