Figures 1 & 2 Lockable Lid preparation
5.3
Installing the Lid assembly to WC.
5.3.1
Lid installation guidelines
1.
Insuring the arrow symbol on the Lid is facing forward towards the front of the WC
Insert the Lid assembly into the WC pan as indicated at Fig. 3.
2
With the Lid assembly engaged with the WC rim, slide the Lid backwards, until the
Lid cover plate positively locates to the WC bowl. The whole underside perimeter of
cover plate must be in contact with top face of WC rim with little or no front to back
or side to side sliding movement, Fig. 4.
3
Holding the Lid located to the WC bowl, using a torque wrench & 6mm A/F bit, turn
the recessed Lock bolt CW until it begins to tighten. Using the torque wrench &
adaptor, continue to tighten Lock screw to torque between 12Nm & 14Nm.
4
WARNING! Check Lid is securely fitted (Fig. 4), by pushing Lid side to side & front
to back (there should be no movement of Lid in relation to the WC) before leaving
the facility unattended:-