10.3 Hydraulic Fitting Torque
Tightening Flare Type Tube Fittings
1.
Check flare and flare seat for defects that
might cause leakage.
2.
Align tube with fitting before tightening.
3.
Hand-tighten swivel nut until snug.
4.
To prevent twisting the tube, use two
wrenches. Place one wrench on the
connector body and tighten the swivel nut
with the second. Torque to values shown.
If a torque wrench is not available, use the FFFT
(Flats From Finger Tight) method.
Hydraulic Fitting Torque
Tube
Size
OD
Hex
Size
Across
Flats
Torque value
Flats From
Finger Tight
Inches Inches
lbf•ft
N•m
Flats
Turns
3/16
7/16
6
8
2
1/6
1/4
9/16
11–12
15–17
2
1/6
5/16
5/8
14–16
19–22
2
1/6
3/8
11/16
20–22
27–30
1-1/4
1/6
1/2
7/8
44–48
59–65
1
1/6
5/8
1
50–58
68–79
1
1/6
3/4
1-1/4
79–88
107–119
1
1/8
1
1-5/8
117–125 158–170
1
1/8