27-05-19 UNI-SAN Domestic Instructions Page 6 

 

 

Emery paper strip 
50 mm O.D. hole saw (for cutting out UNI-SAN Bottom Inlet Valve hole) 
42 mm O.D. hole saw (for cutting out tank vent pipe hole) 
Other sizes as required, holes cut must be no more than 3 mm larger than the OD of the valve socket thread. 

 

8.  GENERAL INSTALLATION ASPECTS AND ELECTRICAL DATA 

 

8.1 General 

 

 
1. Where a permit or consent is required, it is recommended that the unit should be installed by a registered plumber 

and the power supply should be connected by a registered electrician. It is the responsibility of the installer to 
obtain the necessary permits and ensure full compliance with all applicable local regulations. The owner or owner's 
agent must ensure that the UNI-SAN is compatible with the existing or proposed plumbing system design. 

 
2. The installation of the unit and the swing check valve must comply with the following conditions  

- they are easily accessible for servicing;  
- service fixtures and appliances located on the same floor level as the unit, each must have a waste trap installed; 

for below-floor installations refer to Appendix C. 

- are in a clean, dry, non-floodable position, protected from UV and on a permanently sturdy support;  
- design against overflow, flooding, unwarranted interferences or excessive moisture; 
- protect from freezing of liquids in the unit and the pipework; 
- the tank is installed with the screwed inspection lid on top; 
- unless the unit is installed below the floor level as in Appendix C, 

Figure 7c

, install an individual UNI-SAN Bottom 

Inlet Valve for the shower tray and one for the bath; 

- if installed outside or below the floor, the unit is installed according to Appendix C. 
- all the requirements in these instructions are met. 

 
3. Cut holes carefully. Check via the inspection lid, the position of fittings inside the tank before drilling. For PVC 

valve sockets, allow room for the back-nut. Take care not to score or mark the tank as this may weaken it. 

 
4. Modifications not described in this manual and without written authorisation by a Wallace representative will nullify 

the Wallace Pumps warranty and durability compliance. 

 

8.2 Plumbing

 

 
1.The connection to the soil and waste drain system must be carried out in accordance with the Building and 

Plumbing Code. The connection of the unit's delivery pipe to a soil or waste pipe should be kept at least 0.5 metre 
distance from any other connection. Also it must not be connected in a section of the pipe which runs the risk of 
being flooded creating a back pressure down the pipework to the unit. The connection point is usually 600 mm 
above the lowest W.C. connection or the lowest gully trap. Delivery into a gully trap must have an elbow to direct 
the flow downwards. The connection of the delivery from the unit to a soil or waste pipe should be a swept 
inspection bend in the direction of flow of the soil or waste pipe. 

 
2. Any horizontal section of the delivery pipework should always have a continuous rise towards the soil or waste 

pipe connection. It should never be level or have a fall. The pipework must be securely strapped and isolated from 
the building structure to prevent vibration and noise transmission. 

 
3. Install only the supplied swing check valve within one metre of the pump in a vertical position.  

WARNING : Use of non-approved non-return valve will invalidate the WALLACE UNI-SAN warranty. The valve 
must be installed in an easily accessible position for future servicing.  

 
4.  All pumped appliances, such as washing machines and dishwashers, must discharge via an approved waste 

system which includes an air gap and a trap.  BEWARE OF OVER TEMPERATURE DISHCARGE FORM 
WASHING MACHINES. 

 
5.  Ensure that the 32 mm tank vent is installed in the top of the unit and that it extends full-bore to the external air 

(the minimum height must be 50mm above the overflow level of the highest fixture discharging into the WALLACE 
UNI-SAN) or terminated elsewhere as described in the current Building & Plumbing regulations.  

DO NOT use air 

admittance venting devices

 as they do not let air out of the tank, eg: a "Hunter Valve". 

 
6.  It is important from a health and safety reason and for the protection of property, that an overflow relief pipe is 

plumbed and delivered to a safe and visible area in the event that the discharge flows into the UNI-SAN exceed 
the pump hydraulic performance capability or caused by a mechanical failure or a pipe blockage. Pumped 
appliances and water supply can be safeguarded as per Section 10.4 (Overflow). 

 

Содержание UNI-SAN

Страница 1: ...l view and connections 2 2 Product overview 3 3 Applications 3 4 Features benefits 4 5 Overall building design and Pump hydraulic capability 4 6 Warning for your safety 5 7 List of fittings supplied r...

Страница 2: ...k except over the float switch for fixtures or appliances which have an overflow level higher than the unit Allow room for the back nut when cutting the hole Check that either the inflow liquid or the...

Страница 3: ...there is one for domestic applications and one for commercial Both units are the same dimensions and pumping performance the major differences are in the materials of construction level control and mo...

Страница 4: ...ensions and hydraulic capabilities of the unit Ascertain that the combined inflows into the unit at any time do not exceed 35 litres min Measure the overall height of the delivery pipework from the bo...

Страница 5: ...g are coloured in accordance with the following code Earth Green Yellow Neutral Blue Phase Brown 7 LIST OF FITTINGS SUPPLIED AND RECOMMENDED EXTRAS 7 1 Unpacking And Inspection Your UNI SAN package sh...

Страница 6: ...The connection to the soil and waste drain system must be carried out in accordance with the Building and Plumbing Code The connection of the unit s delivery pipe to a soil or waste pipe should be kep...

Страница 7: ...nk to the valve socket 40 50mm Waste Pipe DRAIN from Floor Waste Gully Trap plumbed as per Appendix C Figure 7c to the valve socket 50 100mm Waste Pipe VENT from WALLACE UNI SAN to approved terminatio...

Страница 8: ...BSPF Refer to Section 5 Hydraulic capability to determine the correct pipe size from this connection Slip the delivery pipe in the ends of the swing check valve supplied Check the direction of flow a...

Страница 9: ...leaned regularly The unit is not designed as a kitchen waste disposal unit or for the disposal of sewage Refer to our office for the UNI SAN model or other options 10 2 External cleaning The external...

Страница 10: ...unit or any other property caused by any un authorised modifications repairs in contravention with the Company s instructions or by use of materials or fittings not supplied by Wallace Pumps Where a c...

Страница 11: ...parameters Refer Section 5 Building design If the building or application design is in excess of the pump capability shown on the chart call our office for advice Check that the pump is not pumping th...

Страница 12: ...the pump Remove the obstruction Fit 25 mm SWING CHECK VALVE supplied installed in a vertical section of pipe as close as possible within 1 metre of the pump 7 Pump runs and makes a rattling noise Soli...

Страница 13: ...otor and pump assembly Do NOT overtighten Check the condition of the o ring Make sure it is not pinched Replace if necessary Check the pressure on the o ring Adjust the 4 nuts as per above Do NOT over...

Страница 14: ...ND OR BATH CONNECTED Install unshared UNI SAN Bottom Inlet Valve and waste trap for each OVERFLOW PROTECTION Our warranty excludes any damage caused by an overflow Because of the danger of flooding ca...

Страница 15: ...turn non clog full flow ball valve must be installed in a vertical position in the delivery line within a metre of the pump 4 an OVERFLOW PIPE should be installed to maintain the maximum 900mm height...

Отзывы: