9
Walker Inc., NEO Permanent Lifting Magnets
LIFT MAGNETS MODELS:
NEO-1000 & NEO-2000
unless the magnet is in contact with a load of a thickness equal to those listed
manual. Attempting to energize or de-energize this magnet without a load or
high probability of personal injury due to handle spring back.
RULES
8
Carefully set the load down. To release the load,
grip the handle fi rmly, unlock the handle shaft, and
turn the handle to the “OFF” position. Lift the mag-
net slightly to be sure the load has been released.
3
Position the magnet so the load remains level.
4
To energize magnet, grip the handle fi rmly and pull
the handle from its locked position. Turn the handle to
the “ON” position. Then be sure to return the handle
to the FULLY LOCKED POSITION. Release the
handle.
7
ALWAYS STAY
CLEAR OF THE LOAD.
Guide the load by pushing or pulling the
edges. This keeps your entire body clear of the load at all
times. DO NOT guide the load by pushing or pulling the
Magnet. NEVER get in a position where you could get hit
with load if it dropped.
NEVER
re-energize the magnet until it has been placed in contact with the load to
be lifted. Prematurely energizing the magnet could cause unwanted materials to
be attracted to the magnet.
PERSONAL INJURY MAY RESULT.
CAUTION