11
Technical Data
Section 3:
Technical Data
Environmental Conditions
All dryers are designed to be safe under the following conditions:
• Indoor use
• Altitude up to 2,000m
•
Ambient temperature 5°C (41°F) to 50°C (122°F)
•
Mains supply voltage fluctuations not to /- 10% of nominal
For operation extended from the above conditions, please contact Walker Filtration.
Rated Conditions
Measurement
Performance
Inlet pressure
7 barg
101.5 psig
Inlet temperature
35°C
95°F
Relative humidity of air at inlet
95%
Pressure dewpoint, standard version
-40°C
-40°F
Specified Limitation for Operation
Measurement
Performance
Maximum inlet air pressure
13 barg
188.5 psig
Minimum inlet air pressure
4 barg
58 psig
Maximum ambient air temperature
50°C
122°F
Minimum ambient air temperature
5°C
41°F
Pressure dewpoint (LED & DMC Controller)
-20°C to -74°C
-4°F to -100°F
Electrical supply voltage (LED Controller)
115 VAC or 230 VAC
Electrical supply voltage (DMC Controller)
24 VDC
Excessive vibrations from external sources may cause
failure of this product.