25
8.
Operating:
a.
Insert nozzle into grain with airslide complete-
ly open.
b.
Close airslide slowly until hose pulsates and
then open slide an additional 1 ½ inches.
c.
Operate machine at this setting for ten min-
utes to warm system before putting under full
load.
d. After warm-up period, bring machine to full
capacity.
e.
Close airslide until intake line starts to pulsate.
Open slide slightly to stop pulsation.
f.
Watch glass window in receiver tank. Material
should move past the window for the best
performance.
9.
Maximum Capacity:
a.
Place the nozzle into the grain with the inlet
below the surface of the grain but not below
the airslide. It is necessary that some air be
allowed to enter through the airslide.
b.
Open the airslide completely to start. Close
airslide until the hose starts to pulsate. Then
open it until the pulsing stops. This will give a
balanced grain and airflow condition.
c.
Watch for grain build-up on the window in the
receiver tank. Grain must not lie stationary on
the window. If grain builds up on the window,
decrease the amount of grain entering the
nozzle by opening the airslide.
FIG. 9
WINDOW
FIG. 8
AIRSLIDE
Содержание Agri-Vac 3510
Страница 2: ......
Страница 4: ......
Страница 9: ...NOTES...
Страница 22: ...NOTES...
Страница 45: ...35 FIG 22 STEERING WHEEL BUSHING 5 Grease steering wheel bushing...
Страница 58: ...NOTES...
Страница 62: ...NOTES...
Страница 66: ...57 NOTES...
Страница 67: ...57 NOTES...
Страница 69: ......