17
NOTE:
These conversions should only be carried out by qualified persons. All connections must
be checked for leaks before re-commissioning the appliance.
For all the following conversion instructions, the side access panels have to be removed
(Remove two screws at bottom of each side panel).
All conversion details apply to both L/Hand and R/Hand burners.
For all relevant gas specifications refer to the table at the end of this section.
1.
Remove the following:-
Two side access panels.
Main burner injectors.
2.
Remove main burner injectors and replace with correct size
injectors as shown in ‘Gas Specifications’ tables at rear of this
section.
1.
Remove the following:-
Gas control knobs from front of unit.
Two front control panels.
2.
Light main burners and check flame size on
Low
position.
Adjust burner gas control valve low fire adjustment screw as
shown in ‘Gas Specifications’ tables at rear of this section.
NOTE: ‘Low Fire Screw’ should be sealed with coloured paint on
completion of low fire adjustment.
3.
Refit the following:-
Two side access panels.
Two front control panels.
Gas control knobs.
Main Burner
Injector
Low Fire
Adjustment
Содержание SNB8200G