20
- All Other Countries:
(*) NOTE:
(*) Measure burner operating pressure at manifold test point with both burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
apart from when converting between gasses, if required.
(**) TOWN GAS Only - Burner operating pressure is to be adjusted using Town Gas
adjustable gas regulator supplied.
Refer to ‘Gas Conversion and Specifications’ section of this manual for further details.
Main Burner Injectors
Ø 1.85mm
Ø 3.50mm
Low Fire:
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
2 turns out (ccw)
4 turns out (ccw)
Supply Pressure
1.13 - 3.40 kPa
0.76 - 1.50 kPa
Burner Operating Pressure (*)
1.00 kPa
0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure)
Main Burner Injectors
Ø 1.15mm
Ø 1.10mm
Low Fire:
Size
Ø 1.00mm
Ø 1.00mm
Adjustment
½ turn out (ccw)
½ turn out (ccw)
Supply Pressure
2.75 - 4.50 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.55 kPa
2.55 kPa
Gas Regulator Cap Screw