27
Gas Specifications
- Non CE Only (Australia / New Zealand):
- CE Only
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
*
The burner operating pressure is to be measured at the manifold test point with two
burners operating at the ‘High’ setting. The operating pressure is ex-factory set through
the appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to the ‘Gas Conversion’ section for details).
Gas Conversion and Specifications
Natural Gas
LP Gas (Propane)
Open Burner
Main Burner Injectors
Ø 2.45 mm
Ø 1.50 mm
Pilot Burner ('PF' Option Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Main Burner
Ø 2.60 mm
Ø 1.60 mm
Pilot Burner
0.35
0.23
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Operating Pressure
0.95 kPa (*)
2.6 kPa (*)
Gas Regulator Cap Screw
Oven
Burner Aeration Setting
Fully Open
Fully Open
Burner Aeration Setting
Fully Open
Fully Open
Natural Gas
(G20)
Propane
(G31)
Open Burner
Main Burner Injectors
Ø 2.30 mm
Ø 1.40 mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Main Burner
Ø 2.60 mm
Ø 1.60 mm
Pilot Burner
0.35
0.23
Supply Pressure
20 mbar
30 / 37 mbar
Operating Pressure
9.5 mbar
26 mbar
Gas Regulator Cap Screw
Oven
Burner Aeration Setting
Fully Open
Fully Open
Burner Aeration Setting
Fully Open
Fully Open
Содержание RNL8510GC
Страница 7: ...5 Dimensions RN L 8510GC RN L 8510GC RN L 8513GC Cooktop Options...
Страница 8: ...6 Dimensions RN L 8610GC RN L 8610GC RN L 8613GC RN L 8616GC RN L 8619GC Cooktop Options...
Страница 9: ...7 Dimensions RN L 8810GC RN L 8810GC RN L 8813GC RN L 8816GC RN L 8819GC Cooktop Options...
Страница 33: ...31...
Страница 34: ...32...