background image

22 

Gas Conversion and Specifications

 

 - All Other Markets: 

 

 

NOTE: 



(*) Measure Burner operating pressure at manifold test point with two burners operating at 
'High Flame' setting. 



NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, 
unless when converting between gases, if required. 



(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator 
supplied. 



Refer to information in this section for further details. 

 

 

Natural Gas 

Town Gas (**) 

Open Burner 

Main Burner 

Ø 2.45mm 

Ø 4.50mm 

Pilot Burner ('PF' Option Only) 

0.30 0.60 

Oven 

Main Burner 

Ø 2.6mm 

Ø 5.0mm 

Pilot Burner 

0.35 0.60 

Low Fire 

Ø 1.5mm 

Ø 2.50mm 

Burner Aeration Setting 

Fully Open 

Fully Open 

Supply Pressure 

1.13 - 3-4 kPa 

0.75 - 1.50 kPa 

Burner Operating Pressure (*) 

0.95 kPa 

0.63 kPa 

Gas Regulator Cap Screw 

 

Adjustable Regulator 

(Adjust to Burner Operating 

Pressure specified). 

 

LP Gas (Propane) 

Butane 

Open Burner 

Main Burner 

Ø 1.50mm 

Ø 1.40mm 

Pilot Burner ('PF' Option Only) 

0.20 0.20 

Oven 

Main Burner 

Ø 1.60mm 

Ø 1.45mm 

Pilot Burner 

0.23 

Low Fire 

Ø 0.95mm 

Burner Aeration Setting 

Fully Open 

Supply Pressure 

2.75 - 4.50 kPa 

Burner Operating Pressure (*) 

2.6 kPa 

Gas Regulator Cap Screw 

 

Содержание RN8910GC

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l RN8910GC RNL8910GC Gas Range Convection Oven Date Purchased Serial Number Dealer Service Provider 232780 8 For use in GB IE ...

Страница 2: ...s tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel ...

Страница 3: ...n Clearances Assembly Gas Connection Electrical Connection Commissioning Operation 10 Operation Guide Description of Controls Open Burners Oven Pilot Ignition Oven Main Burner Thermostat Oven Fan Turning the Oven to Stand By Pilot ON Only Oven Shut Down Cleaning and Maintenance 14 Before Commencing Cleaning Open Burner Cleaning Oven Interior Cleaning Stainless Steel Surfaces Fault Finding 16 Wirin...

Страница 4: ...ANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This appli...

Страница 5: ...l A heavy duty general purpose gas convection oven range created for compact modular kitchens It is available on industrial adjustable feet or on robust rollers Open Burners are available in either PF Pilot and Flame Failure or F Flame Failure Only options Open Burners are fitted with individual flame failure for each open burner The range is fitted with a turbofan convection oven which has pilot ...

Страница 6: ...minal 6 5 kW 7 8 kW 6 5 kW 7 8 kW Reduced 1 75 kW 1 75 kW Gas Rate nett Nominal 0 69 m3 hr 0 83 m3 hr 0 51 kg hr 0 61 kg hr Reduced 0 19 m3 hr 0 14 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 9 5 mbar 26 mbar Gas Connection 3 4 B S P Male Natural Gas LP Gas Propane Input Rate N H G C each Open Burner 28 MJ hr 28 MJ hr Oven 30 MJ hr 30 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 4 ...

Страница 7: ...proximately 130mm from right hand side 32mm from rear and 655mm from floor and is reached from beneath appliance Refer to Dimensions section Connection is BSP male thread Electrical Supply Requirements 230 240 V a c 50 Hz 1 6A 1P N E 0 4kW Oven Fan Motor 100W Natural Gas Town Gas Input Rate N H G C each Open Burner 28MJ hr 28MJ hr Oven 30 MJ hr 30 MJ hr Supply Pressure 1 13 3 40kPa 0 75 1 50kPa Bu...

Страница 8: ...6 Dimensions RN L 8910GC Cooktop Options ...

Страница 9: ...des and manufacturer s specifications shown in this section will void the warranty Components having adjustments protected e g paint sealed by the manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainl...

Страница 10: ...owing checks should be made before installation a Gas Type the appliance has been supplied for is shown on coloured stickers located above gas connection and on rating plate Check this is correct for gas supply appliance is being installed for Gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in Specifications section of this manual Check ga...

Страница 11: ...ked and readily accessible in case of fire 1 Check electricity supply is correct as shown on Rating Plate attached to front right hand corner of bottom sill 2 Appliance is fitted with a 10 Amp 3 pin plug cordset for connection to a properly earthed 3 pin switched electrical socket Commissioning 1 Before leaving new installation a Check the following functions in accordance with operating instructi...

Страница 12: ...at Oven Fan Turning Oven to Stand By Mode Oven Shut Down 1 Description of Controls Heating Indicator Lamp Amber Power Indicator Lamp green Open Burner Option OFF Position HIGH Flame LOW Flame Rear Burner Front Burner Indicators located above the Gas Control Knobs Piezo Igniter Oven Oven Thermostat Temperature Graduations 50 C to 320 C Oven Gas Control OFF Position PILOT Burner HIGH Flame Fig 3 Thi...

Страница 13: ...ion Main burner will extinguish and pilot will remain alight b To turn OFF the PILOT depress and turn gas control knob clockwise back to OFF position PILOT burner will extinguish Open Burners F Flame Failure Option Lighting the Open Burners Flame Failure Protection is incorporated for each burner by way of a thermo electric system which will shut off gas supply to that burner in the event that bur...

Страница 14: ...position This puts gas valve in Stand By position and control of main burner is now carried out through oven thermostat control 4 Turn oven thermostat to desired oven temperature setting required this will regulate gas supply to oven main burner 5 Oven fan will start up and oven main burner will ignite 6 Amber heating indicator light will show oven main burner is ON and oven is heating When amber ...

Страница 15: ...ecently been turned OFF and you want to re light oven the interlock will not allow gas valve to be turned to main burner position until interlock has reset Approximately 1 minute DO NOT FORCE GAS VALVE TO MAIN BURNER POSITION UNTIL INTERLOCK HAS RESET as this will damage gas control valve IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control problems p...

Страница 16: ...erial has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas electrical supply before cleaning the appliance This appliance is not water proof Do not use water jet spray to clean interior or exterior of this appliance Caution Burner Body Spill Tray Pot Stand Burner Cap Burner Mounting ...

Страница 17: ...mpty spill tray and wash with warm soapy water 5 Dry all components thoroughly and re assemble Oven Interior Cleaning 1 Do not use wire brushes steel wool or other abrasive materials to clean oven interior 2 Clean oven regularly with a good quality domestic oven cleaner 3 Weekly Remove and clean any built up of grease etc from oven racks and bottom spill cover 4 Dry oven thoroughly with a dry clot...

Страница 18: ...d Releasing knob before thermo couple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Electromagnet in rear of gas control unit is faulty Hold knob in for at least 20 seconds following ignition of pilot Clean or replace pilot injector Tighten thermocouple connection Check thermo cou...

Страница 19: ...UE CORDSET P N 7 BLUE 8 10 HEAT ORANGE CLEAR MICROSWITCH 003004 COM N O 13 12 E BLOCK TERMINAL E 12 GREEN 11 CAPACITOR BLACK BROWN BLUE BLACK BROWN GREEN MOTOR WHEN VIEWED FROM INSIDE OVEN FAN DIRECTION ANTI CLOCKWISE POWER GREEN 3 4 4 5 5 6 6 1 1 1 2 2 7 7 10 8 8 9 11 11 ...

Страница 20: ...ands burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refit the pot stand supports pot stands burner caps and burner bodies 4 Re light main burners and check flame size on simmer LOW position Adjust low fire adjustment screw on open burner gas control valves to obtain d...

Страница 21: ... bracket Refit main burner and secure clamp bracket Refit sole plate s and lower lintel NOTE There is no Low Fire adjustment on the gas control valve for the GC Oven Refit oven control panel Gas Regulator NAT Gas LPG Butane Only NOTE Gas regulator supplied is convertible between Natural Gas and LP Gas but it s outlet pressure is fixed ex factory and is NOT to be adjusted Town Gas Only 1 Remove slo...

Страница 22: ...late Commissioning Before leaving the installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of appliance as shown in Installation Section of this manual 3 Ensure any adjustments done to components that have adjustments settings paint sealed are to be re sealed DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES Warn...

Страница 23: ... Setting Fully Open Fully Open Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Gas Regulator Cap Screw Natural Gas G20 Propane G31 Open Burner Main Burner Injectors Ø 2 30mm Ø 1 40mm Pilot Burner PF Option Only 0 30 0 20 Oven Main Burner Ø 2 60mm Ø 1 60mm Pilot Burner 0 35 0 23 Low Fire Ø 1 5mm Ø 0 95mm Burner Aeration Setting Fully Open Fully Open Supply Pre...

Страница 24: ...ner Main Burner Ø 2 45mm Ø 4 50mm Pilot Burner PF Option Only 0 30 0 60 Oven Main Burner Ø 2 6mm Ø 5 0mm Pilot Burner 0 35 0 60 Low Fire Ø 1 5mm Ø 2 50mm Burner Aeration Setting Fully Open Fully Open Supply Pressure 1 13 3 4 kPa 0 75 1 50 kPa Burner Operating Pressure 0 95 kPa 0 63 kPa Gas Regulator Cap Screw Adjustable Regulator Adjust to Burner Operating Pressure specified LP Gas Propane Butane ...

Страница 25: ...or Nat Gas 0 30 026136 Pilot Injector LP Gas Butane 0 20 232309 Pilot Injector Town Gas 0 60 229442 Pilot Bracket Assembly 229444 Pilot Burner Shield 227403 Gas Control with Pilot and Flame Failure 227384 Knob Open Burner with Pilot and Flame Failure 227405 Gas Control with Flame Failure 227967 Knob Open Burner with Flame Failure 228167 Thermocouple Front 320mm 228166 Thermocouple Rear 600mm IMPOR...

Страница 26: ...0 60 011987 Thermostat 50 320 C 230312 Gas Control Valve Nova 227508 Piezo Ignitor 018744 Electrode 019407 H T Lead 019479K Motor Kit 010866 Cooling Disc 228116 Fan 200 x 40mm 010909 Motor Capacitor 4µf 013586 Terminal Block PA32 228704 Door Spring Kit 227963 Indicator Neon Orange 227962 Indicator Neon Green 228938 Door Microswitch 230075 Microswitch Insulator 230268 Pilot Viewing Hole Lid 748001 ...

Страница 27: ...ariations possible within the model specified Gas Type Gas Regulators Part No Description Nat Gas LPG Butane 228531 BSP F F Convertible Town Gas 230185 BSP F F Adjustable Models Gas Type to Convert to Nat Gas LPG Butane Town Gas F Models 232796 232795 232797 232798 PF Models 232800 232799 232801 232802 Nat Gas UK 232796 232800 Propane UK 232795 232799 ...

Страница 28: ......

Отзывы: