background image

Installation

 

10 

Clearances 

 

NOTE:  Only non-combustible materials can be used in close proximity to this appliance. 

* Side clearances can be 50mm when the adjacent surface is at least 100mm below cooking surface. 

 

Assembly 

NOTE: 



All Models are delivered completely assembled.  No further assembly is required.  Refer to 
the information below for installation instructions. 



This appliance is fitted with adjustable feet to enable appliance to be positioned securely 
and level.  This should be carried out on completion of gas connection.  Refer to ‘Gas 
Connection’ section. 

 

Optional Accessories (Refer to Replacement Parts List) 



Rear Roller Kit.  For installation details, refer to instructions supplied with each kit. 



Plinth Kit.  For installation details, refer to instructions supplied with each kit. 

 

1. 

Check that all feet (or castors) are securely fitted. 

2. 

Adjust feet to make convection oven range steady and level. 

 

Gas Connection 

NOTE:  ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. 

 

1. 

It is essential that gas supply is correct for appliance being installed and that adequate supply 

pressure and volume are available.  The following checks should be made before installation:- 

a.  Gas Type the appliance has been supplied for is shown on 

coloured stickers located above gas connection and on rating 

plate.  Check that this is correct for gas supply, appliance is being 

installed for.  Gas conversion procedure is detailed in this manual. 

b.  Supply Pressure required for this appliance is shown in 

‘Specifications’ section of this manual.  Check gas supply to ensure 

adequate supply pressure exists. 

c.  The Input Rate of this appliance is shown on Rating Plate and in 

‘Specifications’ section of this manual.  Input rate should be 
checked against available gas supply line capacity.  Particular 

note should be taken if appliance is being added to an 

existing installation. 

 

NOTE:  It is important that adequately sized piping runs directly to connection joint on appliance 

with as few tees and elbows as possible to give maximum supply volume. 

 

2. 

Fit gas regulator supplied, into gas supply line as close to appliance as possible. 

 

NOTE:  Gas pressure regulator provided with this appliance is convertible between Natural Gas and 

LPG as shown in ‘Gas Conversion Section’ in this manual. 

 

Ensure regulator is converted to correct gas type that appliance will operate on. 

 

Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it 
is NOT to be adjusted. 

 

Combustible Surface 

Non Combustible Surface 

Left / Right hand side 

     250mm (*) 

0mm 

Rear 100mm 0mm 

Rating Plate 

Location 

Fig 1 

 
 



This appliance is for professional use and is only to be used by qualified  
persons. 



Only authorised service persons are to carry out installation, servicing or gas 
conversion operations.

 

Caution 

Содержание RN8510GC

Страница 1: ...a t i o n a n d O p e r a t i o n M a n u a l RN8510GC RN8610GC RN8810GC Gas Range Convection Oven Date Purchased Serial Number Dealer Service Provider 228680 23 RNL8510GC RNL8610GC RNL8810GC For use...

Страница 2: ...tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 T...

Страница 3: ...on Requirements Unpacking Location Clearances Assembly Gas Connection Electrical Connection Commissioning Operation 12 Operation Guide Description of Controls Open Burners Griddles Oven Pilot Ignition...

Страница 4: ...PLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STO...

Страница 5: ...RN 1 8819GC Gas Range Convection Oven 2 Open Burners 900mm Griddle NOTE 1 Back Options Standard Models L Low Back Models 2 Open Burner Options F With Flame Failure Protection PF With Pilot and Flame F...

Страница 6: ...1 75 kW 1 85 kW 1 75 kW 1 95 kW Gas Rate nett Nominal 0 69 m3 hr 0 58 m3 hr 0 83 m3 hr 0 51 kg hr 0 43 kg hr 0 61 kg hr Reduced 0 19 m3 hr 0 20 m3 hr 0 14 kg hr 0 15 kg hr Supply Pressure 20 mbar 37 m...

Страница 7: ...from rear and 655mm from floor and is reached from beneath appliance Refer to Dimensions section Connection is BSP male thread Electrical Supply Requirements 230 240 V a c 50 Hz 1 6A 1P N E 0 4kW Oven...

Страница 8: ...Dimensions 6 RN L 8510GC RN L 8510GC RN L 8513GC Cooktop Options...

Страница 9: ...Dimensions 7 RN L 8610GC RN L 8610GC RN L 8613GC RN L 8616GC RN L 8619GC Cooktop Options...

Страница 10: ...Dimensions 8 RN L 8810GC RN L 8810GC RN L 8813GC RN L 8816GC RN L 8819GC Cooktop Options...

Страница 11: ...section will void the warranty Components having adjustments protected e g paint sealed by manufacturer are only to be adjusted by an authorised service agent They are not to be adjusted by the instal...

Страница 12: ...rating plate Check that this is correct for gas supply appliance is being installed for Gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in S...

Страница 13: ...ible in case of fire 1 Check electricity supply is correct as shown on Rating Plate attached to front right hand corner of bottom sill 2 Appliance is fitted with a 10 Amp 3 pin plug cordset for connec...

Страница 14: ...ription of Controls Heating Indicator Lamp Amber Power Indicator Lamp green Fig 3 Griddle Option Burner Control OFF Position PILOT Burner HIGH Flame LOW Flame Gas Control Knobs Piezo Igniter Located h...

Страница 15: ...ually re light burner each time that it is turned ON as burner will automatically light itself off the pilot burner Flame Failure Protection is incorporated for each burner by way of a thermo electric...

Страница 16: ...oven is fitted with a pilot as a standard option and flame failure protection which is incorporated by way of a thermo electric system for the main burner Flame failure protection will shut off gas su...

Страница 17: ...osition this will turn oven main burner OFF but will leave oven pilot burner ON 2 In this position pilot burner will remain alight but oven main burner will not operate until thermostat control knob i...

Страница 18: ...ing material has been completely removed after each cleaning To keep your Cooktop clean and operating at peak efficiency follow the procedures shown overleaf Always turn off the gas electrical supply...

Страница 19: ...e surface thoroughly with a scraper tool and brush off any deposits with a soft bristled brush 2 Stubborn or accumulated carbon deposits can be removed with a griddle stone or a scotch bright pad 3 Wi...

Страница 20: ...Weekly Remove and clean any built up of grease etc from oven racks and bottom spill cover 4 Dry oven thoroughly with a dry cloth and polish with a soft dry cloth Stainless Steel Surfaces 1 Clean stai...

Страница 21: ...ple has heated Pilot flame too small Gas pressure too low Partially blocked pilot injector Thermocouple connection to gas control is loose or faulty Thermocouple faulty Electromagnet in rear of gas co...

Страница 22: ...BROWN BLUE CORDSET P N 7 BLUE 8 10 HEAT ORANGE CLEAR MICROSWITCH 003004 COM N O 13 12 E BLOCK TERMINAL E 12 GREEN 11 CAPACITOR BLACK BROWN BLUE BLACK BROWN GREEN MOTOR WHEN VIEWED FROM INSIDE OVEN FAN...

Страница 23: ...nds burner caps and burner bodies and the pot stand supports 2 Remove injectors and replace with correct size injectors as shown in Gas Specifications Tables at end of this section 3 Refit the pot sta...

Страница 24: ...ight main burners and check flame size on Low flame position Adjust low fire adjustment screw on open burner gas control valves to obtain desired flame size NOTE The Low Fire Screw should be sealed wi...

Страница 25: ...Adjust pressure adjusting screw to achieve correct burner operating pressure NOTE Measure operating pressure at manifold test point with two burners operating at High Flame setting 4 Verify operating...

Страница 26: ...10mm 1 30mm Pilot Burner 0 35 0 23 Main Burner 2 60mm 1 60mm Pilot Burner 0 35 0 23 Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Gas Regulator Cap Screw Oven...

Страница 27: ...g out Gas Conversion if required Refer to information in this section for details Natural Gas G20 Propane G31 Open Burner Main Burner Injectors 2 30mm 1 40mm Pilot Burner PF Option Only 0 30 0 20 Grid...

Страница 28: ...40mm Pilot Burner 0 35 0 60 Burner Aeration Setting Fully open Fully open Oven Main Burner 2 6mm 5 0mm Pilot Burner 0 35 0 60 Burner Aeration Setting Fully Open Fully Open Supply Pressure 1 13 3 4 kPa...

Страница 29: ...Flame Failure 227967 Knob Open Burner with Flame Failure 228167 Thermocouple Front 320mm 228166 Thermocouple Rear 600mm Griddle 014105 Griddle Burner 032210 Burner Injector Nat Gas 2 10mm 032130 Burne...

Страница 30: ...013586 Terminal Block PA32 228704 Door Spring Kit 227963 Indicator Neon Orange 227962 Indicator Neon Green 228938 Door Microswitch 230075 Microswitch Insulator 230268 Pilot Viewing Hole Lid 748001 Tap...

Страница 31: ...85 231884 231886 231887 RN8610GC 231889 231888 231890 231891 RN8810GC 231893 231892 231894 231895 RN8510GC 231897 231896 231898 231899 RN8610GC 231901 231900 231902 231903 RN8810GC 231905 231904 23190...

Страница 32: ......

Отзывы: