18
Griddle
These griddles are fitted with a pilot as a standard option and Flame Failure Protection, which is
incorporated by way of a thermo-electric system for each main burner. Flame Failure Protection will shut
off the gas supply to that burner in the event that the pilot for that burner goes out, so that un-burnt gas is
not expelled.
This is an important safety feature which is slowly becoming law throughout the
world
.
Lighting the Griddle
a. Depress the gas control knob and rotate anti-clockwise to the ‘PILOT’ position.
b. With the gas control knob depressed, press the piezo ignition button to ignite the pilot burner.
Repeat Items 1 to 2 until the pilot is lit.
c. Release the gas control knob approximately 10-20 seconds after lighting the pilot.
d. The pilot should now remain alight - if not, repeat Steps (a to (c above.
e. ‘Full Flame’ can now be achieved by depressing and rotating the gas control knob anti-clockwise
to the first stop.
f. Low flame can be achieved by depressing the gas control knob and rotating fully anti-clockwise
to the ‘Low Flame’ position.
g. When the main burner is not required, depress and turn the gas control knob clockwise back to
the ‘OFF’ position.
Turning 'OFF' the Griddle Burner / Pilot
a. To turn 'OFF' the griddle, but keep the pilot burner alight, rotate the gas control knob to the
'PILOT' position. The griddle burner will extinguish and the pilot will remain alight.
b. To turn 'OFF' the 'PILOT', depress and turn the gas control knob clockwise back to the ‘OFF’
position. The 'PILOT' burner will extinguish.
Operation
C
AUTION
:
The griddle plate temperature reaches over 300°C in hottest points during
normal operation at 'Full Flame' setting
.