19
Gas Conversion and Specifications
Low Fire Adjustment
a. To adjust the burner low fire adjustment, adjust the
low fire adjustment screw on the open burner gas
control valves to obtain the desired flame size.
NOTE: The ‘Low Fire Screw’ should be sealed with
coloured paint on completion of the low fire
adjustment.
On completion of the main and pilot burner adjustments, check
all gas connections for leakages and then turn off the main
burners at the gas control knob. Turn off the main gas supply.
Refit all the panels and control knobs to the appliance.
Gas Regulator
NOTE: The regulator supplied is convertible between Natural Gas and LPG, but it’s outlet pressure
is fixed ex-factory and is NOT to be adjusted.
1.
Ensure that the gas supply is turned ‘OFF’ at the mains.
2.
Unscrew the hexagonal cap (23mm A/F) from the regulator.
3.
Un-clip the plastic pin from the cap, rotate the pin and re-fit it back to
the cap the correct way for the gas type to be used.
(Either ‘LP’ or
‘NAT’ should be visible on the flank of the pin once
re-fitted to the cap)
.
4.
Screw the cap back into the regulator.
Gas Type Identification Label
On completion of the gas conversion, replace the gas type identification label located at:-
- The rear of the appliance, above the gas connection.
- Beside the rating plate.
Low Fire
Adjusting Screw
Fig 10
NOTE, Pin rotated
for Natural Gas
NOTE, Pin
rotated for LPG
Fig 11
Содержание PC8140G
Страница 7: ...5 Dimensions PC L 8140G...
Страница 19: ...17 Wiring Schematics PC8140G Pasta Cooker...
Страница 25: ...23...