Waldorf PC8140G Скачать руководство пользователя страница 11

8. 

Turn ‘OFF’ the mains gas supply and bleed the 

gas out of the appliance gas lines. 

9. 

Turn ‘ON’ the gas supply and the appliance. 

10.  Verify the operating pressure remains correct  
11.  Check the pilot flame size.  (Re-adjust if 

required by changing the pilot injector.  Refer 

to the Gas Conversion Section). 

 

 

 

 

 

 
 

 

Water Connection 

NOTE:  The water connection shall be installed in accordance with local water regulations in force 

and the applicable standard/code, e.g. EN 1717 in UK / Ireland, PCA in Australia. 

 
A cold water supply must be connected to the water inlet connection (R

1

/

2

" BSP), located 50 mm from 

the LH side, 556 mm from rear and 151 mm from the floor. 

 

The water inlet pressure must be as follows:- 

 

Minimum water supply pressure 150 kPa (22 psi). 

Maximum water supply pressure 550 kPa (80 psi). 

 

Drainage Connection 

• 

The water is drained from the appliance by means of a valve located behind the front control panel. 

• 

A waste water tundish must be fitted below the appliance drain outlet.  This should be a minimum of 
127mm (5”) major diameter. 

• 

If required the drain outlet can be extended in order to exit above the tundish.  All drain piping must 
be with materials suitable for conveying boiling water. 

• 

Drain connection is R1" BSP drain / overflow. 

 

Commissioning 

The following commissioning checks must be carried out before the pasta cooker is handed 

over for use, to ensure that the unit operates correctly and the operator(s) understand the 

correct operating procedure. 

1. 

Before leaving the new installation; 
a.  Check the following functions in accordance with the operating instructions specified in the 

‘Operation’ section of this manual. 

• 

Light the Pilot Burner. 

• 

Light the Main Burner. 

 

b.  Ensure that each operator has been instructed in the areas of correct lighting, operation, and 

shutdown procedures for the appliance. 

2. 

This manual must be kept by the owner for future reference and a record of 

Date of Purchase

Date of Installation 

and 

Serial Number of Unit 

recorded and kept with this manual.  

(These 

details can be found on the Rating Plate attached to the inner R/H side of the front 

access door panel.  Refer to Figure 1 in the 'Installation' section).

 

 

NOTE:  If for some reason it is not possible to get the appliance to operate correctly, shut off the 

gas supply and contact the supplier of this unit. 

Installation

 

Fig 2 

Gas Control 

Valve 

Burner Operating 

Pressure Test Point 

Содержание PC8140G

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Pasta Cooker PC8140G PCL8140G Date Purchased Serial Number Dealer Service Provider 230008 10 For use in GB IE...

Страница 2: ...0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NEW...

Страница 3: ...ances Assembly Gas Connection Water Connection Drainage Connection Commissioning Operation 10 Operation Guide Description of Controls Before Use Filling the Tank Lighting the Pilot Burner Lighting the...

Страница 4: ...THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED...

Страница 5: ...ist for details Plinth Kit Gas Supply Requirements Australia New Zealand Only UK Only Appliance Classification Category II2H3P Flue Type A1 NOTE The burner operating pressure is to be measured at the...

Страница 6: ...ional rear connection is available Connection is 3 4 BSP male Water Supply Requirements Cold water connection is 1 2 tube connection via 15 mm crox fitting located 50 mm from the LH side 556 mm from r...

Страница 7: ...5 Dimensions PC L 8140G...

Страница 8: ...must be carried out by qualified service persons only Failure to install equipment to the relevant codes and manufacturer s specifications shown in this section will void the warranty Components havin...

Страница 9: ...In order to facilitate easy operation drainage and servicing of the appliance a minimum of 600 mm clearance should be maintained at the front of the appliance Any gas burning appliance requires adequa...

Страница 10: ...e NOTE The gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per the Gas Conversion Section in this manual Ensure the regulator is converted to the corr...

Страница 11: ...to exit above the tundish All drain piping must be with materials suitable for conveying boiling water Drain connection is R1 BSP drain overflow Commissioning The following commissioning checks must...

Страница 12: ...r and pilot burner and is controlled by a single gas controller with flame failure protection to control both main burner and pilot Open tank design to simplify cleaning operation PC8140G Pasta Cooker...

Страница 13: ...water flow out of the water supply nozzle that just causes water to continually flow out of the overflow This method provides Maintained water level for cooking Skimming or flushing effect to prevent...

Страница 14: ...ot ignite repeat Items 1 to 6 above Lighting the Main Burner 1 Depress and rotate the gas control knob to the High Flame position the main burner will now ignite automatically off the pilot burner 2 T...

Страница 15: ...re that protective gloves are worn during the cleaning process Clean the pan regularly after each use Draining and Cleaning Opening the Drain Valve a Lift the locking slide on valve handle Fig 5 to re...

Страница 16: ...brush use a wooden probe to dislodge any obstruction 4 Clean the interior and exterior of the pan regularly at the end of each day Do not use wire brushes on the pan Clean using a mild detergent and a...

Страница 17: ...and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cle...

Страница 18: ...hecks out satis but the problem still persists The gas control valve is defective and needs replacement Pilot Burner delay in ignition of main burners Check operating pressure as stated in Installatio...

Страница 19: ...17 Wiring Schematics PC8140G Pasta Cooker...

Страница 20: ...the end of this section Main Burner Injectors 1 Unscrew and remove the main burner injectors 12 7 mm A F located in front of main burner venturi openings 2 Determine the correct injectors for the cor...

Страница 21: ...supplied is convertible between Natural Gas and LPG but it s outlet pressure is fixed ex factory and is NOT to be adjusted 1 Ensure that the gas supply is turned OFF at the mains 2 Unscrew the hexago...

Страница 22: ...rdance with the operating instructions specified in the Operation section of this manual Light the Pilot Burners Light the Main Burners Check the Thermostat operation Ensure that all the controls oper...

Страница 23: ...Refer to the Gas Conversion and Specification Section for further details Natural Gas LP Gas Propane Main Burner Injectors 3 10mm 1 90mm Pilot Burner Injectors 0 62 0 35 Low Fire Screw 1 55mm 2 turns...

Страница 24: ...a Cooker Basket 320 x 165mm Optional Accessory 229836 Pasta Cooker Basket 165 x 165mm 229707 Pasta Cooker Basket Drain Tray 229682 Basket Support Frame 227856 Door Magnet 019390 Water Drain Valve 2298...

Страница 25: ...23...

Отзывы: