![Waldorf PC8140G Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/waldorf/pc8140g/pc8140g_installation-and-operation-manual_3179003011.webp)
9
8.
Turn ‘OFF’ the mains gas supply and bleed the
gas out of the appliance gas lines.
9.
Turn ‘ON’ the gas supply and the appliance.
10. Verify the operating pressure remains correct
11. Check the pilot flame size. (Re-adjust if
required by changing the pilot injector. Refer
to the Gas Conversion Section).
Water Connection
NOTE: The water connection shall be installed in accordance with local water regulations in force
and the applicable standard/code, e.g. EN 1717 in UK / Ireland, PCA in Australia.
A cold water supply must be connected to the water inlet connection (R
1
/
2
" BSP), located 50 mm from
the LH side, 556 mm from rear and 151 mm from the floor.
The water inlet pressure must be as follows:-
Minimum water supply pressure 150 kPa (22 psi).
Maximum water supply pressure 550 kPa (80 psi).
Drainage Connection
•
The water is drained from the appliance by means of a valve located behind the front control panel.
•
A waste water tundish must be fitted below the appliance drain outlet. This should be a minimum of
127mm (5”) major diameter.
•
If required the drain outlet can be extended in order to exit above the tundish. All drain piping must
be with materials suitable for conveying boiling water.
•
Drain connection is R1" BSP drain / overflow.
Commissioning
The following commissioning checks must be carried out before the pasta cooker is handed
over for use, to ensure that the unit operates correctly and the operator(s) understand the
correct operating procedure.
1.
Before leaving the new installation;
a. Check the following functions in accordance with the operating instructions specified in the
‘Operation’ section of this manual.
•
Light the Pilot Burner.
•
Light the Main Burner.
b. Ensure that each operator has been instructed in the areas of correct lighting, operation, and
shutdown procedures for the appliance.
2.
This manual must be kept by the owner for future reference and a record of
Date of Purchase
,
Date of Installation
and
Serial Number of Unit
recorded and kept with this manual.
(These
details can be found on the Rating Plate attached to the inner R/H side of the front
access door panel. Refer to Figure 1 in the 'Installation' section).
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this unit.