11 

Operation

 

Before Use 

1. 

Check that the gas supply is turned on. 

2. 

Check that no foreign articles are in the tank. 

 

 

Filling the Tank 

NOTE:  Tank capacity - 40 Ltrs of water. 

 

1. 

Before filling the tank, always check that the drain valve behind the door is closed.  A locking slide is 

provided on the valve and this should always be locked in position during use. 

2. 

Turn the water supply 'ON'.  Open the appliance water valve and fill the tank with water. 

3. 

The water level will remain at a constant height as there is an overflow at the front of the tank. 

4. 

During cooking, the water level will reduce as it evaporates as steam when boiling and when it 

overflows as loaded baskets are dropped into the tank. 

5. 

To maintain the correct water level, the water tap should be adjusted to give a water flow out of the 
water supply nozzle that just causes water to continually flow out of the overflow. 

 

 This 

method 

provides: 

 

• 

Maintained water level for cooking. 

• 

Skimming or flushing effect to prevent the cooking water becoming gummed up with pasta 
residue. 

WARNING: 

 

G

REAT

 

CARE

 

MUST

 

BE

 

TAKEN

 

BY

 

THE

 

OPERATOR

 

TO

 

USE

 

THE

 

PASTA

 

COOKER

 

SAFELY

TO

 

GUARD

 

AGAINST

 

THE

 

RISK

 

OF

 

INJURY

 

AND

 

FIRE

• 

DO NOT 

LEAVE

 

THE

 

PASTA

 

COOKER

 

UNATTENDED

 

DURING

 

OPERATION

• 

DO NOT 

OVER

 

FILL

 

THE

 

WATER

 

IN

 

THE

 

PASTA

 

COOKER

 

ABOVE

 

THE

 

UPPER

 

FILL

 

LEVEL

 

MARK

• 

DO NOT 

ALLOW

 

THE

 

WATER

 

IN

 

THE

 

PASTA

 

COOKER

 

TO

 

FALL

 

BELOW

 

THE

 

LOWER

 

LEVEL

 

MARK

• 

DO NOT 

USE

 

FLAMMIBLE

 

SOLVENTS

 

AND

 

CLEANING

 

AIDS

 

ON

 

OR

 

IN

 

CLOSE

 

PROXIMITY

 

TO

 

THE

 

PASTA

 

COOKER

 

WHILST

 

THE

 

PASTA

 

COOKER

 

IS

 

STILL

 HOT. 

Fig 4 

CORRECT LEVEL FOR WATER WHEN COOKING, 

KEEP TOPPED UP. 

INDICATES MINIMUM (SAFE) LEVEL.  WATER 

LEVEL SHOULD BE TOPPED UP. 

WARNING: 

 

D

ANGER

 

OF

 

FIRE

 

EXISTS

 

IF

 

THE

 

WATER

 

LEVEL

 

IS

 

BELOW

 

THE

 

MINIMUM

 'LOW' 

INDICATED

 

LEVEL

N

EVER

 O

PERATE

 

THE

 A

PPLIANCE

 E

MPTY

Содержание PC8140G

Страница 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Pasta Cooker PC8140G PCL8140G Date Purchased Serial Number Dealer Service Provider 230008 10 For use in GB IE...

Страница 2: ...0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NEW...

Страница 3: ...ances Assembly Gas Connection Water Connection Drainage Connection Commissioning Operation 10 Operation Guide Description of Controls Before Use Filling the Tank Lighting the Pilot Burner Lighting the...

Страница 4: ...THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED...

Страница 5: ...ist for details Plinth Kit Gas Supply Requirements Australia New Zealand Only UK Only Appliance Classification Category II2H3P Flue Type A1 NOTE The burner operating pressure is to be measured at the...

Страница 6: ...ional rear connection is available Connection is 3 4 BSP male Water Supply Requirements Cold water connection is 1 2 tube connection via 15 mm crox fitting located 50 mm from the LH side 556 mm from r...

Страница 7: ...5 Dimensions PC L 8140G...

Страница 8: ...must be carried out by qualified service persons only Failure to install equipment to the relevant codes and manufacturer s specifications shown in this section will void the warranty Components havin...

Страница 9: ...In order to facilitate easy operation drainage and servicing of the appliance a minimum of 600 mm clearance should be maintained at the front of the appliance Any gas burning appliance requires adequa...

Страница 10: ...e NOTE The gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per the Gas Conversion Section in this manual Ensure the regulator is converted to the corr...

Страница 11: ...to exit above the tundish All drain piping must be with materials suitable for conveying boiling water Drain connection is R1 BSP drain overflow Commissioning The following commissioning checks must...

Страница 12: ...r and pilot burner and is controlled by a single gas controller with flame failure protection to control both main burner and pilot Open tank design to simplify cleaning operation PC8140G Pasta Cooker...

Страница 13: ...water flow out of the water supply nozzle that just causes water to continually flow out of the overflow This method provides Maintained water level for cooking Skimming or flushing effect to prevent...

Страница 14: ...ot ignite repeat Items 1 to 6 above Lighting the Main Burner 1 Depress and rotate the gas control knob to the High Flame position the main burner will now ignite automatically off the pilot burner 2 T...

Страница 15: ...re that protective gloves are worn during the cleaning process Clean the pan regularly after each use Draining and Cleaning Opening the Drain Valve a Lift the locking slide on valve handle Fig 5 to re...

Страница 16: ...brush use a wooden probe to dislodge any obstruction 4 Clean the interior and exterior of the pan regularly at the end of each day Do not use wire brushes on the pan Clean using a mild detergent and a...

Страница 17: ...and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cle...

Страница 18: ...hecks out satis but the problem still persists The gas control valve is defective and needs replacement Pilot Burner delay in ignition of main burners Check operating pressure as stated in Installatio...

Страница 19: ...17 Wiring Schematics PC8140G Pasta Cooker...

Страница 20: ...the end of this section Main Burner Injectors 1 Unscrew and remove the main burner injectors 12 7 mm A F located in front of main burner venturi openings 2 Determine the correct injectors for the cor...

Страница 21: ...supplied is convertible between Natural Gas and LPG but it s outlet pressure is fixed ex factory and is NOT to be adjusted 1 Ensure that the gas supply is turned OFF at the mains 2 Unscrew the hexago...

Страница 22: ...rdance with the operating instructions specified in the Operation section of this manual Light the Pilot Burners Light the Main Burners Check the Thermostat operation Ensure that all the controls oper...

Страница 23: ...Refer to the Gas Conversion and Specification Section for further details Natural Gas LP Gas Propane Main Burner Injectors 3 10mm 1 90mm Pilot Burner Injectors 0 62 0 35 Low Fire Screw 1 55mm 2 turns...

Страница 24: ...a Cooker Basket 320 x 165mm Optional Accessory 229836 Pasta Cooker Basket 165 x 165mm 229707 Pasta Cooker Basket Drain Tray 229682 Basket Support Frame 227856 Door Magnet 019390 Water Drain Valve 2298...

Страница 25: ...23...

Отзывы: