5

DEVICE CONNECTION

4.2

Controls

No

Id

Description

10

Attack Knob

Used for controlling the attack time of the
compression

11

Release Knob

Used to control the release time

12

Main/Side Balance Knob

Balancing the main input signal vs the
sidechain signal

13

Threshold Knob

Used to control the engage level of compres-
sion threshold

14

A/R Man/Auto Switch

Used to choose between two different at-
tack/release timing behaviours

15

Knee Hard/Soft Switch

Used to change between soft and hard com-
pression behaviour

16

Level Knob

Controls the amount of the CV Level Input
signal in case of use as a VCA

17

Compression Type Switch

Chooses between three signal detection
types (Adapt, RMS and Peak)

18

Compression Knob

Controls the amount of compression

19

Bleed Knob

Controls the amount of the original uncom-
pressed signal to the output mix

20

Gain Knob

Controls the overall gain of the processed sig-
nal

5

Device Connection

You now own a fantastic compressor module. It’s time to integrate it in your
modular system.

5.1

Power Connection

The first step is to supply your module with power. The module only requires
reg12V and -12V voltages. These voltages should already be provided
by your modular system’s power supply.

Before connecting any module to the Eurorack bus, it is mandatory to switch the
modular system power off. Otherwise you may severely damage your module
or put yourself at risk.

Please connect the supplied ribbon cable with the smaller 10-way connector to
the module’s Eurorack bus connector and with the larger 16-way connector to
your modular system bus board.

Eurorack connectors are usually orientated in a way that the -12V supply line is
located at the bottom. The cmp1 module follows the same convention.
The red line of the ribbon cable should show to the bottom of your bus board
and at the bottom of your module. Refer to the figure above.

Please make sure the ribbon cable does not swap the lines.

The module can now be installed in the rack using the provided screws, washers
and a Phillips head screwdriver #0. With the module installed, switch the system
power supply on.

6

Содержание CMP1

Страница 1: ...WALDORF CMP1 USER MANUAL Waldorf Music GmbH 2016 11 15 1...

Страница 2: ...mbH extends no liabilities in regard to this manual other than those required by local law This manual or any portion of it may not be reproduced in any form without the manufacturer s written consent...

Страница 3: ...the device in extremely dusty or dirty environments in order to preserve the device s surface finish Ensure that adequate ventilation is available for the device to cool down Do not place the device n...

Страница 4: ...soft cloth or brush to clean the device surface Never use cleaning chemicals as they will damage the device surface 3 Package Contents The cmp1 package contains the following parts cmp1 Compressor Mo...

Страница 5: ...the compressor threshold 4 Comp CV Input Used to control the compression ratio 5 Level Input Used to control the signal level by a Control Voltage Classic VCA instead of compression mode 6 Link Input...

Страница 6: ...ressor module It s time to integrate it in your modular system 5 1 Power Connection The first step is to supply your module with power The module only requires regulated 12V and 12V voltages These vol...

Страница 7: ...is VCA based using the same components you find otherwise in high end analogue compressors Additional features like the output of the detection signal CV control of compressor ratio and threshold and...

Страница 8: ...obs will act as attenuators of the CV inputs 6 4 Attack and Release When the detected level reaches above threshold then compression starts in general as already described and ends when the level fall...

Страница 9: ...manually gain is always required when threshold or compression ratio changes largely In addition to the compressed signal the Bleed knob can be opened to add uncompressed original signal to the output...

Страница 10: ...ne should be modulated by the rhythmic source depending on your Balance level 8 Troubleshooting 8 1 Modules Power Fail Check the orientation of the pin headers on your modules Check if the total power...

Страница 11: ...10 BLOCK DIAGRAM 10 Block Diagram 11...