background image

www.tresore.ch 

 

OPERATING INSTRUCTIONS

 

KEYPAD LOCK  

PAXOS COMPACT DOUBLE LOCK 

Electronic door lock for WA safes  

Issue 08.2020  

 

Содержание PAXOS COMPACT DOUBLE LOCK

Страница 1: ...www tresore ch OPERATING INSTRUCTIONS KEYPAD LOCK PAXOS COMPACT DOUBLE LOCK Electronic door lock for WA safes Issue 08 2020...

Страница 2: ...ave chosen a product tested according to EN1143 1 A Swiss quality product with VdS tested security Please read these instructions carefully before commissioning your safe Your contact for questions WA...

Страница 3: ...2 Ocb2 4 1 2 5 Master code 1 4 1 2 6 Master code 2 MA2 4 1 2 7 Employee codes c1 to z1 and c2 to z2 5 1 2 8 Cancellation or conversion of an employee code c to z 5 1 2 9 Deletion of an employee code 0...

Страница 4: ...Open lock 1 appears on the display enter code 11 22 33 10 Enter or 11 22 33 20 Enter 4 The lock opens and the message Lock opens lock open Open bolt appears 5 Only now can the opening rotary handle be...

Страница 5: ...per lock body User code 1 lock 1 Oca1 11 22 33 10 Enter User code 2 lock 1 Ocb1 11 22 33 20 Enter User code 1 lock 2 Oca2 12 22 33 10 Enter User code 2 lock 2 Ocb2 12 22 33 20 Enter Master code 1 Lock...

Страница 6: ...afe door 3 Press the Enter key confirm the question Change code again with Enter 4 Enter opening code 1 Oca1 for first time programming 11 22 33 10 Enter 5 Enter new code 6 8 digits and confirm with E...

Страница 7: ...he display shows Change Ocb2 made 7 Pull the opening handle upwards the lock closes test the newly programmed codes at least 3 times with the door open 1 2 5 Master code 1 Procedure 1 Open lock 1 with...

Страница 8: ...gits and confirm with Enter 13 Enter the new code again and confirm with Enter The display shows Change e g Occ2 made 14 Pull the opening handle upwards the lock closes test the newly programmed codes...

Страница 9: ...st be increased by three The entry triggers the alarm and opens the lock anyway Syntax Addition Input 96 3 99 99 97 3 100 00 98 3 101 01 99 3 102 02 00 3 03 03 05 3 08 08 Examples opening code 192739...

Страница 10: ...More time functions Confirm with Enter Confirm Opening delay in case of threat with Enter Enter master code 11 99 88 77 Enter opening delay in minutes and seconds e g 15 00 confirm with Enter The disp...

Страница 11: ...d the programming are not deleted by this Do not use accumulators rechargeable as their capacity is not sufficient for trouble free operation 3 1 Opening the battery compartment The battery compartmen...

Страница 12: ...ing backwards is also too easy Important passwords should be reconstructable 4 1 2 How to create a secure password The first rule A password is only secure if it remains secret Remember passwords don...

Страница 13: ...______________________________________________________________ _______________________________________________________________________________ _________________________________________________________...

Отзывы: