1.2.9. Deletion of an employee code 03 OCc1 to 95 OC95-1
Procedure
1. With the lock open, press the "ENTER" key, confirm the "Code functions"
question again with "ENTER
2. Select opening code 03 OCc1, 04 OCd1, 05 OCe1 to 95 OC95-1 with the
arrow key and confirm with ENTER.
3. Select "Delete" with the arrow key and confirm with "ENTER".
4. Enter existing opening code, confirm with "ENTER", confirm query "Delete
code?" with "ENTER".
5. Code deleted" appears on the display
1.2.10. Opening the safe under threat
If the locking system is connected to an alarm system, a silent alarm (which
cannot be heard by you) can be triggered to the alarm control panel when a
normal code is entered to open the lock. To trigger the threat alarm, the value of
the opening code must be increased by "three". The entry triggers the alarm and
opens the lock anyway.
Syntax:
Addition
Input
96 + 3 = 99
99
97 + 3 =
100
00
98 + 3 =
101
01
99 + 3 =
102
02
00 + 3 = 03
03
05 + 3 = 08
08
Examples:
opening code 192739 becomes threat alarm trigger code 192742,
code 4719226 becomes code 4719229, or code 22315698 becomes
code 22315601.
ATTENTION:
Care must be taken that the addition does not result in a
valid opening code
1.2.11. Programming date and time
The Paxos Compact lock offers four-time functions in the standard version:
A)
Opening delay:
from 1 second to 99 minutes
B)
Opening delay at
threat:
from 1 second to 99 minutes
when threatened, if the last number of your code is increased by 3 digits, the
programmed opening delay runs visibly on the display and the lock can be
opened only after the programmed time has elapsed
C)
max. opening time:
from 1 second to 99 minutes
programmable
D)
Print event memory: only possible in connection with options box