Use and Operation
This equipment can kill the harmful germ and aglae in the apuarium and the pond which
offer the heathy environment to the fishes. When the water under the irradiation of ultra
-
violet radiation in a short period ,the germ and pathogen in the water will be killed then.
This equipent is not sell with the pump, please buy the pump.
1. Please connect the inlet pipe with the outlet of the water pump. 5. Please connect the
outlet pipe with the other filter or the pond and fix it .After the inspection of the pipe and
the connecting part, the water circulation can be started then.
2. Please check it when the water started circulation or not after several mintes.
3.
Tuening on the electrical source ,the UV filter begin to work.
4. The detailed sketch map of usage can be pound in the packing box.
Replacing the UVC bulb and clean quartz glass
• Unplug the light‘s power plug.
• Switch off the pump and safeguard it from being turneb on again Unintentionally.
• Unscrew the big screw on the body shell,pull out the device head, then you can change
the uv lamp.
• Use key or other tool to pull the interspaces between the glass and shell,then they will be
departed,and you can do the cleaning.
• Clean the quartz glass sleeve from the outside with a damp cloth.
• Check the quartz glass sleeve for damage before putting it back.
• When replacing the tube,make sure there is no water in it, it is better to use a dry cloth
to hold the tube.
• Please make sure all seal parts are clean and all into correct position, especially the o-
ring.
•
After assembly, first turn on the power source of the pump, then plug this equipment.
Troubleshooting
Trouble
Possible Cause
Solution
Cloudy water UVC Lamp dose not light up.
Check electrical connection.
Cleaning quartz glass tube soiled.
Cleaning.
Incorrect pump flow rate (unit).
See installation.
Brown suspendedmaterlal, deposits
at the bottom.
Remove alga and leaves,prevent the ingress
of dirt.
Pond extremely dirty.
Check water valus,change the water.
Lamp has no UVC capacity.
Check the lamp,change the lamp afte 8000 h.
Содержание 10030602
Страница 1: ...Teichkl rer 10030602...