11
3.0 OPERATION
3.1
Pump Operation & Programming
The EW an EK pumps have a digital display, two LED indicators and three pushbutton keys to
change the pump speed and programming.
A.
Operation Overview
360
Power ON
EXT
360
T-5
Set mode
+
+
UP stroke rate
DOWN stroke rate
EXT operation display
Operating at
max spm while
both keys are
pressed.
MANUAL operation display
UP stroke rate
DOWN stroke rate
Setting display
MOVES
to next
menu
SCROLL
thu choices
DISPLAY
Operating condition and
programming is displayed
UP Key
Increases numeric values.
Used with Start/Stop key to
change the programs.
DOWN Key
Decreases numeric values.
Used with Start/Stop key to
set the pump to operate in
EXT mode.
3 6 0
ON
STOP
STOP/START Key
Manually stops and starts the
pump. Used with Up/Down
keys for programming and
mode selection.
ON LED
Indicates AC power to the
pump and goes off and on
with each pump stroke.
STOP LED
ORANGE when Pre-Stop signal
is input (EW only). RED when
a START/STOP signal is input