A. Outdoor Water Heater Location
❑
Outdoor water heaters must be installed outdoors .
❑
Protected from freezing temperatures .
❑
Proper clearance from combustible surfaces observed
.
❑
Sufficient fresh air supply for proper operation of
water heater .
❑
Air supply free of corrosive elements and
flammable vapors .
❑
Provisions made to protect area from water damage .
❑
Sufficient room to service heater .
❑
Combustible materials, such as clothing, cleaning
materials, rags, etc . clear of the heater and
vent piping .
❑
Water heater is properly attached to the wall .
B. Water Supply
❑
Water supply has sufficient pressure .
❑
Air purged from water heater and piping .
❑
Water connections tight and free of leaks .
❑
Water filter is clean and in place .
❑
Materials used are as instructed in this manual .
❑
Water pipes are insulated and protected from
freezing .
C. Gas Supply
❑
Gas type matches rating plate .
❑
Gas supply pressure is sufficient for the water heater .
❑
Gas line equipped with shut-off valve, union and
sediment trap .
❑
Approved pipe joint compound used .
❑
Soap and water solution used to check all connections
and fittings for possible gas leak .
❑
Gas Company inspected installation (if required) .
D. Relief Valve
❑
Pressure Relief valve properly installed and discharge
line run to open drain .
❑
Discharge line protected from freezing .
E. Electrical Wiring
❑
voltage matches rating plate .
❑
Water heater is properly grounded .
❑
Supply cord and/or wiring meets all local codes .
Installation Check List